IMPORTANT SAFETY INSTRUCTIONS

When installing and using this electrical equipment, basic safety precautions should always
be followed, including the following: READ AND FOLLOW ALL INSTRUCTIONS
• To minimise the risk of gas build-up in the cell housing, you must ensure there is sufficient water flow
through the cell when the unit is on and producing chlorine.
• It is essential that your pool pump circulates sufficient water through the cell housing to completely fill
the cell housing with water during the chlorination process.
• Periodically check the paddle of the safety flow switch to ensure it is free to move back and forth and
that the lock nut is done up hand tight.
ü
Diagram A
CORRECT OPERATION
WITH A PUMP RUNNING
û
Diagram B
INCORRECT OPERATION
WITH A PUMP RUNNING
WARNING: To reduce the risk of injury, do not permit children to use this product
unless they are closely supervised at all times. SAVE THESE INSTRUCTIONS.
WARNING: Risk of Electric Shock. Power connections and wiring must be carried
out by an authorised electrician. Connect only to a branch circuit protected by a
ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot
verify that the circuit is protected by a GFCI.
The unit must be connected only to a supply circuit that is protected by a
ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the
installer and should be tested on a routine basis. To test the GFCI, push the test
button. The GFCI should interrupt power. Push the reset button. Power should
be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If
the GFCI interrupts power to the pump without the test button being pushed,
a ground current is flowing, indicating the possibility of an electric shock. Do
not use this pump. Disconnect the pump and have the problem corrected by a
qualified service representative before using.
• Always check for the latest versions of installation and
operation instructions that support these products.
Simply scan this QR code, or go to:
https://qr.daveywater.com/VZRY
WARNING – To reduce the risk of electric shock, replace
damaged cord immediately. SAVE THESE INSTRUCTIONS.