LOW FLOW ALARM
Should the EcoSalt2 flow switch register a flow rate below 3.6m3/h (16 gal/min), the EcoSalt2 will enter LOW
FLOW ALARM:
In LOW FLOW ALARM, the EcoSalt2 will not produce chlorine. Once the flow switch registers flow above 60L/
min (16 gal/min), the EcoSalt2 will return to normal operation. To achieve best efficiency, the EcoSalt2 cell should
be installed such that turbulent water is limited as much as possible. Do not install a 90° elbow closer that 200mm
(8") from the cell's inlet barrel union. Isolation valves used where equipment is located below pool water level,
should also be installed no closer than 200mm (8") from inlet barrel union. This will assist laminar flow.
ADD SALT ALARM
Should the EcoSalt2 register low conductivity within the cell, this could be triggered by cold water (below
15ºC / 59ºF), or a salt concentration below its minimum (refer to recommended salt range section in the
manual), the EcoSalt2 will enter ADD SALT ALARM. Additional salt may be added to overcome a lower
temperature. However, the maximum salt level should also be considered and if water temperature drops too
far, the system should be turned off. If salt levels are in range and water temperature is above 15°C (59°F),
your cell may need to be cleaned.
Once the EcoSalt2 registers a salt concentration within range (refer to recommended salt range section in the
manual), the EcoSalt2 will return to normal operation.
LOW SALT CUT-OUT ALARM
Should the salt concentration continue to be diluted, the EcoSalt2 will enter LOW SALT CUT-OUT ALARM.
ALARM
LOW FLOW
ALARM
ADD SALT
ALARM
LOW SALT CUT-OUT
21