Herunterladen Inhalt Inhalt Diese Seite drucken

Schneider Airsystems CPM 260-10-10 WX Original Bedienungsanleitung Seite 4

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
GB
CPM 260-10-10 WX
Table of contents - Part 1
1.1
Scope of delivery ......................
1.2
Conventional use ......................
1.3
Technical data ..........................
1.4
Components.............................
1.5
Commissioning .........................
1.6
Adjusting the working pressure...
1.7
Water separator with filter..........
1.8
Vessel inspections .....................
1.1 Scope of delivery
– Compressor with instruction manual
– Oil dipstick
1.2 Conventional use
The compressor is designed for generating
and storing compressed air only. Com-
pressed air is only suitable for compressed
air tools/devices/machines.
Any other type of use is considered contrary
to the intended use.
The compressor must not be used in poten-
tially explosive areas. Combustible, caustic
or toxic gases must not be sucked in!
1.3 Technical data
see Fig. 1a
1.4 Components
01
Compressor unit
02
Intake filter
03
Oil dipstick
04
Oil drain screw
06
Pressure pipe
07
Check valve
08
Vessel
09
Condensate drain valve
10
Pressure switch with ON/OFF switch
11
Safety valve
I/2
12
Pressure gauge (vessel pressure)
13
Pressure gauge (working pressure)
2
14
Electric motor
2
18
Pressure reducer
2
19
Quick-action coupling (clean, regu-
lated compressed air)
2
32
Water separator with filter
2
2
1.5 Commissioning
2
1.5.1
Before first use
Replace the sealing plug with the oil dip-
2
stick (item 03) and fill with compressor
oil. For oil quantity, see "Technical data"
chapter.
1.6 Adjusting the working pres-
sure
Rotate clockwise = pressure is increased.
Rotate anticlockwise = pressure is reduced.
1.7 Water separator with filter
Semi-automatic condensate drainage:
turn the condensate drain valve anticlock-
wise 1/4 of a turn. Under 1 bar: condensate
drains.
Manual drainage: turn the condensate
drain valve clockwise and push it up. The
condensate drains away.
1.8 Vessel inspections
No inspections are specified for the ves-
sels.
We recommend that a "qualified person"
perform a pressure test on the vessel, de-
pending on its rate of utilisation, after 10
years in accordance with the Ordinance on
Industrial Safety and Health. Contact any of
our service partners.
The statutory specified inspections must
be arranged in accordance with the appli-
cable regulations of the respective coun-
try in which the vessel is used.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

A 212 001

Inhaltsverzeichnis