R
ASSEMBLY INSTRUCTION
E
F
Important:
Push and turn simultaneously.
3.
Torque Value 2.0Nm
G
PRESS FIRMLY
4.
Wrench size
13 mm
1.
Disassembly (open twist lock):
1. Press with screw driver to unlock
2. Turn bushing while still pressing locking.
I
powerCON TRUE1
Torx size
T8
Torque Value 0.7 Nm
1.
5.
2.
Strom- und Datenverbindung
Slide the cable into the contacts and clamp with
the screw with Torx size T8.
Wiring
VDE
Þ
L
brown
Þ
N
blue
Þ
green / yellow
2.
Slide chuck onto insert (1) and then both into
housing (2).
Important: Align the chuck by positioning the
nose into keyway.
6.
Slide the cable clamp bushing up the cable and
tighten it with the tool as shown.
Important:
Yellow O-ring to hide to achieve IP
protection (6).
(Tool available: Art. No. HTAC)
CAUTION
To ensure protection
category, do not expose
the connection to
bending forces (e.g. do
not attach loads to the
FORCE
cable, no free-dangling
cable windings etc.).
Illustrations are used by kind permission of Neutrik AG
UL
black
white
green