Occupation of the DIP switches:
Setting the DMX-
DIP-switch no.
starting address:
Projector number
DMX-starting
& channels
address
Device 1 - channels 1-5
Device 2 - channels 6-10
Device 3 - channels 11-15
Device 4 - channels 16-20
Device 5 - channels 21-25
Controlling:
After having addressed all LED spots, you may now start operating these via your lighting controller.
DMX-protocol
Channel DMX Value Function
1
0-255
2
0-255
3
0-255
4
0-255
5
0-255
MASTER/SLAVE
For the master/slave function, set DIP switch 10 to ON on the master device and DIP switch 1 to ON on
the slave device.
CLEANING AND MAINTENANCE
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no serviceable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers.
Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
1
2
3
4
1
2
4
8
On
Off
Off
On
Off
On
Off
On
Off
On
Off
red
green
blue
dimmer
strobe
0.5-13 Hz
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
5
6
7
8
9
16
32
64 128 256
%
0-100
0-100
0-100
0-100
23/24