Herunterladen Inhalt Inhalt Diese Seite drucken

Husqvarna K 770 Dry Cut Bedienungsanweisung Seite 61

Vorschau ausblenden Andere Handbücher für K 770 Dry Cut:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2. Turn the adjustment screw (B) until the adjustment
nut (A) is opposite the mark on the cover.
3. Tighten the bolts.
The illustration shows the correct tension. The
adjustment nut is opposite the mark on the cover.
Starter housing
WARNING:
always use eye protection when you replace
the recoil spring or the starter rope. There is
tension in the recoil spring when it is wound
in the starter housing. The recoil spring can
eject and cause injury.
To remove the starter housing
1. Loosen the 4 screws on the starter housing.
861 - 005 - 22.04.2022
B
A
Always be careful and
2. Remove the starter housing.
To replace a damaged starter rope
1. Hold the starter rope pulley with your thumb. Pull the
starter rope approximately 30 cm and put it in the
cut-out of the starter pulley.
2. Let the rope pulley rotate slowly in the opposite
direction to release the spring tension.
3. Remove the remaining starter rope.
4. Do a check that the recoil spring operates correctly.
5. Put the new starter rope through the hole in the
starter housing and in the rope pulley.
6. Attach the starter rope to the rope pulley.
7. Tighten the connection fully. Make sure that the free
end of the starter rope is as short as possible.
8. Attach the end of the starter rope in the starter
handle as shown in the illustration.