Step
Description
4
Connect the AS-i cables in accordance in the diagram below:
Attention
If the motor starter is the last station on the AS-Interface line, you must
terminate the ends of the AS-i cables with cable end covers
(Order No.: 3RK1901-1MN00) in order to obtain degree of protection IP65. To
allow this, leave the cable ends projecting by about 10 cm beyond the AS-inter-
face.
5
Connect the motor starter and motor with the motor connecting cable.
Secure the connections with the locking devices.
6
Connect the data lines to the data tee connector.
Secure the connection with the locking device.
7
Connect the terminating connector to the last load feeder (non-assigned con-
nection on the last data tee connector).
Secure the connections with the locking devices.
Table 3-6: Installation: motor nearby (Forts.)
ECOFAST Motor Starters
GWA 4NEB 950 5221-12 DS 02
Installation of Motor Starters
1
2
3RK1901-1MN00
5
4
AUX PWR
AS-i
3
3-7