Maintenance and repair
Bosch Rexroth AG, MIT: LU 2/P-24V-3L, 3 842 557 976/2020-08

11.1 Cleaning and care

Failure of bearings
Applying grease-dissolving substances to the bearing points, e.g. during cleaning,
leads to bearing failure. There is a risk of damage to property, and the service life
may be reduced.
Keep degreasers or aggressive cleaning agents away from the bearings!
Only clean the product with a damp cloth.
Failure of the toothed belt
Applying grease-dissolving substances to the toothed belt, e.g. when cleaning, leads
to the failure of the toothed belt. There is a risk of damage to property.
Keep degreasers or corrosive cleaning agents away from the toothed belt!
Only clean the product with a damp cloth.

11.2 Inspection

• Periodically check the system status for possible errors by visual inspection of the
LED indicators and the display (see page 36).
• Check the lubrication unit regularly for dirt and leakage.
• Regularly check the fi lling fi lter in the fi lling opening for contamination.

11.3 Maintenance

The automatic lubrication unit LU 2/P-24V-3L is maintenance free.
11.3.1
Refi lling oil
See chapter 9.1.1.

11.4 Spare parts

For a list of spare parts, see spare parts list in MTpro, 3 842 539 057
(download: www.boschrexroth.com/mtpro).