Herunterladen Inhalt Inhalt Diese Seite drucken

Operating The Pump - EINHELL GE-AW 1144 SMART Originalbetriebsanleitung

Hauswasserautomat
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
5.6.3 Resetting the registration
If the blue LED (Fig. 5/Item C) lights up con-
tinuously when your pump is started for the
fi rst time, this is because the pump has been
registered already. The pump must be reset and
registered with your data. Make sure you have
your pump's purchase receipt and serial number
ready to hand and get in touch with our customer
service center .
6. Operation
6.1 LED indicator (Fig. 5)
6.1.1 Status LEDs
The current operating status is signaled via the
LED indicator (Fig. 5/Item B).
Yellow is lit:
The pump is connected to the power supply.
Yellow and green are lit:
The pump is in operation and starts up as soon
as a consumer is opened for drawing off pumped
medium.
Yellow is blinking:
The pump is building up pressure (e.g. a water
tap is closed) and then switches off automatically.
Yellow, green and red are lit:
The pump is running dry without any pumped
medium. The pump will make 3 attempts to elimi-
nate the dry running before the dry running guard
fi nally trips.
Yellow and red are lit:
The dry running guard has tripped; it is no longer
possible to draw in the pumped medium. Use the
troubleshooting instructions to fi nd the cause of
the fault (e.g. a leaking intake line) and rectify it.
Then press the RESTART button (Fig. 5/Item A) to
reactivate the pump.
6.1.2 Network LED
The pump uses the network LED (Fig. 5/Item C)
to signal its network status.
Blue is blinking:
The pump is searching for a connection to the
network.
Anl_GE_AW_1144_SMART_SPK13.indb 21
Anl_GE_AW_1144_SMART_SPK13.indb 21
GB
Blue is lit:
The pump is connected to the network.

6.2 Operating the pump

The pump has numerous operating modes, which
means that you can put the pump into operation
in diff erent ways. You can use the app to call up
numerous setting options for your pump and to
view its performance data. The app also presents
you with error messages and warnings during
operation.
You can operate the pump manually at its control
panel as well as by using the app. When the pump
is started independently of the operating mode,
the pump will be set to an automatic domestic
water system mode. Regardless of the mode
being used, the pump will always switch on when
the discharge side is open, and it will switch off
again automatically when no pumped medium is
discharged.
The current operating status is signaled via the
LED indicator (Fig. 5/Item B) (see the chapter
"LED indicator").
The fl ow and discharge switch cannot be adjus-
ted or activated, it is fully automatic.
Priming process
The pump is started in one of the operating mo-
des and immediately begins to run. The pump
will make 3 attempts to eliminate the dry running
before the dry running guard fi nally trips.
During operation the pump will build up pres-
sure and will switch off automatically when the
discharge line is closed. When the pressure in
the discharge line drops, e.g. because a shut-off
mechanism is opened, the pump will switch on
again.
6.2.1 Manual operation
The pump can be switched on and off manually
at any time using the RESTART button (Fig. 5/
Item A). This does not require the pump to be re-
gistered. There is no way of setting the maximum
running time of the pump in this mode.
6.2.2 Remote control using the app
The pump can be switched on and off manually
by means of the app and your smart-phone. A
start or stop command is then sent to the pump
via the network.
- 21 -
10.01.2022 09:16:31
10.01.2022 09:16:31

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

41.803.80

Inhaltsverzeichnis