Verifying Multi-Path Driver Functionality

1 Right-click My Computer and select Manage.
2 Expand Storage and click Disk Management.
One disk is displayed for each LUN assigned in the storage.
3 Ensure that each LUN is configured as a Basic disk.
4 Repeat step 1 to step 3 on the remaining nodes.

Verifying and Upgrading the Firmware

Discover the host server's direct-attached storage using the Modular Disk
Storage Manager software that is installed on the host server.
Verify that the firmware for the following storage components is at the
minimum required version. Refer to the Solutions Deliverable List (SDL)
for the firmware version requirements.
MD3000i storage system firmware
MD1000 expansion enclosure firmware

Configuring up your EqualLogic iSCSI Storage

Creating Volumes

Before data can be stored, the PS5000XV physical disks must be configured
into usable components, known as volumes. A volume represents a portion of
the storage pool, with a specific size, access controls, and other attributes.
A volume can be spread across multiple disks and group members and is seen
on the network as an iSCSI target. Volumes are assigned to a pool and can be
easily moved between pools, with no impact on data availability. In addition,
automatic data placement and automatic load balancing occurs within a pool,
based on the overall workload of the storage hardware resources within
the pool.
Configuring Network and Storage for Oracle RAC Database