Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch ISP-EMIL-120 Installationsanleitung Seite 39

Expansion modules
Vorschau ausblenden Andere Handbücher für ISP-EMIL-120:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 13
Expansion modules
No.
45/46
47/48
49/50
51/52
53/54
55/56
Bosch Security Systems B.V.
Connection
Features
s
SP
Not connected, designed for external
resistor (EOL):
Earth inputs for cable shield (if available),
47 and 48 connected internally
PL 5
SP
Not connected, designed for external
resistor (EOL):
PL 6
SP
Not connected, designed for external
resistor (EOL):
12k1 for ISP-EMIL-120 and ISP-PCBA-
EMIL
4k7 for ISP-EMIL-3RDP
Primary line for connection of
detector zone 5 or
Connection of line-fed glass break
detectors
Block-type lock tamper detector zone
at NBS 10, (wire color: 49 = white,
50 = brown)
12k1 for ISP-EMIL-120 and ISP-PCBA-
EMIL
4k7 for ISP-EMIL-3RDP
12k1 for ISP-EMIL-3RDP in case of
line-fed glass break detectors
Primary line for connection of
detector zone 6
Connection of line-fed glass break
detectors
12k1 for ISP-EMIL-120 and ISP-PCBA-
EMIL
4k7 for ISP-EMIL-3RDP
Pin assignment | en
2019-12 | 07 | F.01U.076.548
39

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Isp-pcba-emilIsp-emil-3rdp

Inhaltsverzeichnis