AC: terminal 1: L
DC: terminal 1: +
Sensitivity
If the measured material tends to cake or build up, the sensitivity adjustment switch can
be set to position A to decrease the sensitivity of the probe (factory setting is position B).
The sensitivity for interface applications should be set to position B, while the setting for
high-flow applications should be position A.
Page EN-10
terminal 2: N
19 to 230 V AC, + 10 %, 50 to 60 Hz, 8 VA
terminal 2: -
19 to 55 V DC, + 10 %, 1.5 W
SITRANS LVS200 – INSTRUCTION MANUAL
LED
FSH/FSL adjustment
sensitivity adjustment
B = factory setting,
A = decreased sensitivity
alarm output relay
protective earth terminal
FSH/FSL adjustment (see Switching
Logic on page 11)
sensitivity adjustment:
B = factory setting
A = decreased sensitivity
7ML19985FT61