NOTE
Rating plate
Date of manufacture
Siemens AG
6SE7087-6KP60
SIMOVERT MASTERDRIVES
The derating of the permissible rated current for installation altitudes of
over 1000 m and at ambient temperatures below 45 °C is calculated as
follows:
Total derating =
Derating
K = K
x K
1
2
It must be borne in mind that total derating must not be greater than 1!
Example: Altitude: 3000 m
Ambient temperature: 35 °C
→ Total derating = 0.845 x 1.25 = 1.056 (= 1)
DC/AC DRIVE
6SE7021-0TP60
Z=G91+K80
Fig. 12-2
Example of rating plate (applies only < 22 kW)
The date of manufacture can be derived as follows:
Character
Year of manufacture:
S
T
U
V
Table 12-5
Assignment of characters to the month and year of manufacture
Operating Instructions
x Derating
altitude
K
1
K
2
DC 510 ... 650 V
Character
2004
1 to 9
2005
O
2006
N
2007
D
Technical Data
ambient temperature
= 0.845
= 1.25
Unit designation
List of unit options
Year of manufacture
Month of manufacture
Month of manufacture
January to September
October
November
December