Herunterladen Inhalt Inhalt Diese Seite drucken

Function - Siemens 5TC1 Serie Montageanleitung

Delta i-system; jalousieuhr komfor
Vorschau ausblenden Andere Handbücher für 5TC1 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB

2. Function

The DELTA i-system shutter control timer is a component of the shutter control system
and is installed in combination with the shutter control insert without extension in a flush-
mounting box as per DIN 49307 (deep box recommended). The device permits
programmable and time-controlled switching of a blind/shutter motor up to 1000 W. The
motor used must be equipped with end position limit switches (electronic or mechanical).
Product features overview:
w Simple operation with four keys
w Three program memories for a total of up to 18 switching times
(e. g. nine UP and nine DOWN times).
w Factory-programmed switching times in two program memories (
w Random function
w Astro function
w Individual Astro function with Astro time shift.
w Random and Astro functions can be combined
w Summer/winter time switching by depression of a key
w Individual motor operating times presettable
w Running reserve:
Programmed switching times are permanently safe.
Actual data (time, month, date, day) safe up to 24 hours (no attendance and no
back-up batteries required).
w Sun protection function
w Twilight function
36
Function
,
)
A
B

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis