INSTALLATION INFORMATION:

Attach the ceiling plate using the included plugs and screws to the ceiling on a location of choice. Wall mounting is
not recommended for smoke detection. Remove the red pin from the back side of the smoke alarm. Then put the
detector to the ceiling plate and, twist clockwise to lock it in place. Perform a first test by holding the test key for two
seconds. Also see the paragraph: "Testing".
USING, TESTING AND MAINTENANCE:
Using:
The smoke detector works if the red pin has been removed from the smoke detector and has been mounted to the
ceiling. The unit can only be mounted to the plate if the pin has been removed. The red LED will now flash every
5 minutes. Once smoke is detected, the alarm will sound. Once the smoke disappears, the smoke alarm will stop
automatically. In this case the green LED will flash every 40 seconds. This can be deactivated by pressing the test
button once. A small beep will then indicate that an alarm has occured.
Test:
By pressing the "HUSH/TEST" button 1x, the alarm of the SA-110/SA116 will be checked. Keep the "HUSH/TEST"
pressed for a minimum of 2 seconds. If you immediately hear 3 audio tones the alarm is in excelent working conditi-
on. Check the alarm every week. In alarm status the device generates 85dB(A) sound. Do not test the device using
candles, open fire, cigarettes etc.
Hush function:
The Hush function allows the user to decrease the smoke detectors sensitivity during an alarm. By pressing the
"HUSH/TEST" button the smoke detector is decreased for a period of 10 minutes. The red led flashes 1x every 10
seconds in Hush mode. After 10 minutes the smoke detector resets to its default sensitivity. For example, this can
be used when the smoke detector gives alarm during cooking.
Time-out function:
The time-out function allows you to preventively lower the sensitivity of the smoke detector. By pressing the "HUSH/
TEST" button without an active alarm, you reduce the smoke detectors sensitivity for 10 minutes. The red LED lights
up 1x every 10 seconds during Hush mode.
After 10 minutes the smoke detector resets to its default sensitivity. You can use this mode for example when you
know that a situation (for example: cooking) will product smoke and there is no danger.
ATTENTION:
If the cause of an alarm is unclear, assume it's caused by fire. Immediately evacuate the building.
Keep the smoke detectors out of range of children.
Protect against dust during rennovations. Without protection the smoke detectors will lose their functionality.