Herunterladen Inhalt Inhalt Diese Seite drucken

Indel B TB31.2 Bedienungsanleitung Seite 23

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 45
FAULTS
E RRO R
CO DE
Battery protection or temperature sensor malfunction shutdown
E1
(The voltage is outside the cut-out setting).
Fan over-current cut-out
E2
(The fan loads the electronic unit with more than 1A
Motor start error
E3
(The rotor is blocked or the differential pressure in the refrigeration system is too
high (>5 bar)).
Minimum motor speed error
E4
(If the refrigeration system is too heavily loaded, the motor cannot maintain
minimum speed 1,850 rpm).
Thermal cut-out of electronic unit
E5
(If the refrigeration system has been too heavily loaded, or if the ambient
temperature is high, the electronic unit will run too hot).
E6
Defective electronic unit
E7
Defective temperature sensor (open circuit or short circuit)
ONLY FOR SALES WITHIN THE EUROPEAN COMMUNITY (EU)
This appliance is marked according to the European Directive 2012/19 / EU (WEEE). The symbol
on the product indicates that this product should not be treated as household waste.
Ensure that this product is not entered as part of the flows of municipal waste but treated as
professional WEEE.
ER ROR TYP E
peak
21
).

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tb41.2Tb51.2

Inhaltsverzeichnis