Ausgangsmodul

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Paul Hochköpper GmbH & Co. KG • Postfach 1727 • D-58467 Lüdenscheid • Tel.: (02351)185-0 • Fax: (02351)27666 • e-mail: peha@peha.de • Internet: www.peha.de
Installation- and operating instructions
PHC output modul 940/24 JRM for blinds and roller shutters
8 outputs (2x 4x 1 A) for 4 DC motors from 12 to 24V
Art.no.: 940/24 JRM
1. Description
The PHC output module 940/24 JRM can control four blinds or roller shutters by
the outputs (O0-O3). The module features within the PHC software four separate
channels for time measurement that can be used independently from the blind/roller
shutter functions as virtual outputs. One channel for time measurement is used for
example under the point „sun sensor delay time measurement" in the roller shutters/
blinds group tools for clocking the sun delay.
The module is divided into 4 groups and features 2 inputs to connect 2 external
power supplys
(12-24V
DC). The upper terminal clamps
per 2 output groups
(O0-O1)
with the applied power supply and the lower terminal
(I1+, I1-)
clamps
supplies the lower 2 output groups (O2-O3).
the external positive voltage to one of the motor connections used (O0+ to O3+) for
raising or lowering of a blind or roller shutter. In idle state the motors are connected
by the motor connections (O0- to O3-) with the earth (GND).
2. Connection diagram
External
M
M
voltage
(12 - 24V DC)
+
-
O0+
O0-
I
0+
I
0-
O1+
M0
M1
V0+
V0-
V0+ V0- V0+ V0-
V0+ V0-
Jalousie-/Rollladenmodul
für DC-Antriebe
8 Relaisausgänge für 4 Jalousien/Rollladen
mit Gleichspannungsantrieben 12V - 24V DC
I
max. 2x2x1A
M
N
Art. Nr.: 940/24 JRM
V1+ V1- V1+ V1-
V1+ V1-
V1+
V1-
M3
M2
O2+
O2-
I
1+
I
1-
O3+
+
-
External
voltage
M
M
(12 - 24V DC)
3. Mounting
The installation of the PHC modules may be carried out by authorised technicians
only. During installation the system's electricity has to be switched off. The PHC
module is designed for mounting on a 35mm top hat rail acc. EN 50022 in in-/on-
wall distribution housing. The devices can be mounted directly next to each other.
Attention!! The PHC modules may not be employed in connection with devices that
may endanger people, animals or property when operated.
The following points must be observed:
- the valid laws, standards and regulations
- the technical state of the art during installation
D a t u m
N a m e
DC-Jalousien-/Rolladenmodul
Bearb.
- the PHC manual and the operating instructions of the PHC modules.
G e p r.
- the fact that operating instructions can only cover general regulations and that
N o r m
these regulations must be considered in the context of the PHC system.
Infratec
The following systems may not be switched by PHC modules:
940_24JRM - GEHB - 01
- safety switches such as EMERGENCY OFF
Datentechnik GmbH
- emergency power supplies
Format DIN A4H
Urspr.:
Dateiname:
- fire alarm systems
- emergency lighting systems
4. Data connection
The connection between PHC control unit and other PHC modules is established by
the PHC bus line and the modular connectors of the modules. The module connec-
tors are switched parallel in the modules (except in the PHC power supply unit) and
therefore freely selectable as in- or output. Thus the PHC module can be positioned
anywhere in the data line.
A PHC bus line of 30 cm length is included with every PHC module. It is needed for
connecting a neighbouring module or for connecting a module in the next distributor
row. The modules are supplied with voltage by the bus line. Power needs to be
switched off before disconnecting the bus line.
940-24 JRM (Rev04_100114)
(I0+, I0-)
supplies the up-
The module switches
O1-
Safety recommendation!
During a reset of the PHC system
(e.g. after an interruption of the power
V0+ V0-
supply) all relay outputs are in home
position (idle state).
Since all motor connections (O0- to
29
CEBEC
O3-) are connected to earth (GND) in
idle state it needs to be ensured that
the earth (GND) of the external power
supply is connected to the terminal
clamps I0- and I1-.
V1+ V1-
Coding switch
O3-
Module address
Gehäusebeschriftung
Blatt
5. Coding switch
GB
The output module's address is set by the coding switch built into the PHC control
module. The setting of the coding switch is presented in the PHC software under the
menu item „Components g Edit Modules".
Make sure that no identical module addresses are given for PHC output modules.
The setting of the coding switch may be carried out by technicians only. For this the
PHC module needs to be switched off and it must be ensured that there can be no
electrical discharge.
6. Current consumption
To calculate the current consumption for the power supply, you should assume a
consumption of 60 mA (internal consumption 10 mA, per relay 6 mA). When a relay
is switched on the current increases to 120 mA for about 2 seconds.
7. Technical data
Art. no.
Power supply
PHC system (PHC bus)
Own consumption
In-/output module bus
External voltage
(Terminal I0+, I0-, I1+, I1-)
Relay outputs
(Terminal O0-O3)
Life-time cycle of relays
Coding
Ambient temperature
Storage temperature
Screw terminals
Test specifications
Approbationen
Protection level
Dimensions
8. Permitted loads for the relay outputs
Type of load connected
Motor load
9. Warranty
These operating instructions are an integral part of both the appliance and the terms
of warranty. They must be furnished to the user. The technical design of the ap-
pliance is subject to change without prior notification. PEHA products are manuf-
actured using state of the art technologies in compliance with prevailing national
and international regulations, and are quality tested. If the product should, however,
reveal any defects, PEHA agrees to correct these defects without affecting the rights
of the end user to assert claims against the vendor arising from the purchasing
contract, as follows:
If the complaint is justified and properly filed, PEHA can choose to either correct the
defect or supply a functioning product. Claims above and beyond this, or compensa-
tion for follow-on damages are excluded. The appliance is deemed to be justifiably
defective when it is supplied to the end user in an unusable or severely impaired
state as a result of a design, manufacturing or material error. The warranty does not
apply to natural wear and tear, improper use, incorrect connection, interference with
the appliance or external impacts. The warranty period runs for 24 months from the
1
purchase of the appliance by the end user from a vendor, and expires at the latest
1
Bl.
36 months after manufacture of the appliance. The settlement of warranty claims is
subject to German law.
126098-03
940/24 JRM
Nom. 24 V DC
21-28 V DC (ripple voltage 5 %)
10-60 mA
2 modular sockets 6-pin (PHC bus)
4 terminal clamps for the connection of 2 external
power supplys (12-24V DC)
8 outputs (O0-O3) in 4 groups with 2 terminals
clamps (+ and -) for loads up to 1 A (12-24V DC)
50,000 switchings with max. load
DIP switch, 5-pin (Module address)
+10° to +50°C
-20° to +60°C
max. 2 x 1,5 mm²
EN 60669-2-1
CE KEMA/KEUR CEBEC
IP 20
width = 72 mm
height = 55 mm
Max. output load per output
1 A
GB - 1