Technical Data - Flintec KEK-4 Technisches Handbuch

Kabel-anschlusskasten
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

T
D
ECHNICAL
ATA
Type
Housing material
Dimensions
IP Class
No. Of load cells
Cable connection
Cable in- and outputs
Cable diameter
Corner correction
Grounding
Overvoltage protection
The KEK- 4 stainless steel junction box is prepared for parallel connection of up to 4 load cells.
4 or 6-wire load cells can be connected. The changeover between 4-wire and 6-wire technology is carried
out with insertion bridges.
The corner correction is done with fixed resistors. **
In addition, the terminal box has been prepared for the installation of surge arresters.
**Note: 50 ppm resistors for corner correction are available as a set with 14 values from 0.22 to 4.7
(10 pieces each) are available under article no. 5200-030.
Figure 1: Dimensions in [mm]
Junction Box Type KEK-4 Technical Manual
KEK- 4 v2.0
Stainless steel
105 x 210 x 35 mm
IP 65
Up to 4 load cells 4 or 6 wire connection
Clamping terminals up to 2,5 mm
5x PG9 Cable glands
4-8 mm
Via fixed resistors in signal path
Screw clamp M3
on request
Rev. 2.0.0 December 2022
2