SNT ELI 0-110 W / 30 V – Operation manual
Art.-no.: 50930074
Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and other hazards.
During installation and cable routing, comply with the standards and regulations which apply for SELV.
Do not connect the electronic operating device to a dimmer. The dimmer and operating device may get damaged.
Do not connect the electronic operating device to an electronic switch insert. The switch insert and operating device may get dama-
ged.
These instructions are an integral part of the product, and must remain with the end user.
Device components
(1)
(2)
Figure 1: Device components
(1) Mains cable
(2) Housing (IP 67)
(3) tc-point
(4) Output cable
Function
Intended use
SNT ELI is an electronic operating device for the connection of LED
lamps that are operated with extra low voltage.
- Operation of LED lamps with extra low voltage (SELV) according to
DIN EN 61347-1 and DIN EN 61347-2-13
- Operation indoors and outdoors
Device protection
The LED output of the operating device is no-load proof and has the
following protection devices:
- Electronic short circuit protection
- Electronic overload protection
- Electronic over-temperature protection
In the event of a fault, the output switches off automatically. The output
switches on again autonomously after eliminating the fault.
Telephone +49 2351 936-0
info@insta.de / www.insta.de
tc: 80 °C
(3)
(4)
Figure 2: Device dimensions
Information for electrically skilled persons
Fitting and electrical connection
DANGER!
Mortal danger of electric shock.
Disconnect the device. Cover up live parts.
Fitting the device
At the installation location, drill four holes according to the
dimensions shown in Figure 2.
Attach the supply unit to the installation location with four screws.
Ensure good ventilation around the operating device and do
not cover it. If adjacent devices generate heat, keep a distance of
100 - 150 mm to them.
Connecting the device
The tc-point (3) on the housing must not exceed a temperature of
+80 °C in continuous operation under full load. Otherwise the device
switches off. Therefore, when operating in high ambient temperature,
reduce the load according to Figure 3.
110
100
90
80
70
60
50
40
30
20
10
-40 -30 -20 -10
Figure 3: Load reduction
208
221
0
20
40
50
60
70
Ambient Temperature ta (°C)