Item
Color
Description
(9)
Blue/White
Pry-off tamper, normally closed
If the tamper plate is used, connect wires 7 and 9 to the tamper
loop. Otherwise, use wires 7 and 8 instead.
Package content
1X Magnetic contact
1X Magnet
1X Tamper plate
1X Magnet spacer plate
2X Screws
Specifications
Cable length
Switch close resistance
Switch open resistance
Mounted on non-ferromagnetic material
Minimum mounting distance
between contact and magnet
Approach distance X (switch close)
Removal distance X (switch open)
Approach distance Y (switch close)
Removal distance Y (switch open)
Approach distance Z (switch close)
Removal distance Z (switch open)
Mounted on ferromagnetic material
Minimum mounting distance
between contact and magnet
Approach distance X (switch close)
Removal distance X (switch open)
Approach distance Y (switch close)
Removal distance Y (switch open)
Approach distance Z (switch close)
Removal distance Z (switch open)
Contact type
Contact dimensions
Magnet dimensions
Maximum switch voltage
Maximum switch current
Operating temperature
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
2 / 12
2.5 m
<2 Ω
>10 MΩ
10 mm
5 mm
17 mm
11 mm
20 mm
5 mm
27 mm
8 mm
5 mm
17 mm
9 mm
20 mm
4 mm
19 mm
Change-over
108 x 38.1 x 19.1 mm
108 x 38.1 x 19.1 mm
30 V
0.25 A
−28 to +65°C
EN 50131 Class II: −10 to +55°C
Product warnings
THESE PRODUCTS ARE INTENDED FOR
and disclaimers
SALE TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL
FIRE AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
Environmental
IP68
class
REACH
Product may contain substances that are also
Candidate List substances in a concentration
above 0.1% w/w, per the most recently published
Candidate List found at ECHA Web site.
Safe use information can be found at
https://firesecurityproducts.com/en/content/intrusi
on-intro
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
recyclethis.info
Contact information
www.firesecurityproducts.com or www.aritech.com.
DE: Montageanleitung
Bezeichnung
Bei der DC111-Serie handelt es sich um oberflächenmontierte
Magnetkontakte, die mit einer Einbruchalarmanlage verbunden
werden können. Zusätzliche Sicherheit bieten ein
Sabotagesignal für die Magnetfeldüberwachung sowie einen
Abreisskontakt. Die DC111-Serie kann auf ferromagnetischen
und nicht-ferromagnetischen Oberflächen und Türen
verwendet werden.
Montage
Der Magnetkontakt und der Magnet sollten mithilfe der
Schrauben direkt gegenüberliegend montiert werden, wobei
der Logo-Text in der gleichen Richtung verlaufen muss.
Falls eine Überwachung des Abreisskontakts erforderlich ist,
montieren Sie zuerst die Sabotageplatte (Element 1) mithilfe
der beiden mittleren Löcher (Element 2) an der gewünschten
Position und anschließend den Kontakt. Um den Kontakt und
die Magnetpositionen aufeinander auszurichten, müssen Sie
den Magnet unter Umständen auf der Abstandsplatte
montieren (Element 3).
P/N 1069822 (ML) • REV F • ISS 08NOV22