7 Wiring (Item no. 2525887, 2574213)
Requirements
The mains supply to which you will wire the product must meet the following conditions:
The mains supply includes a light switch. The light switch will be used to switch the
product on and off.
The mains supply is protected by an RCD protective switch.
Wiring
1. Disconnect the power supply.
2. Wire the mains lead. Observe the wire colour coding:
- Blue: Neutral (N)
- Brown: Single phase (L)
- Green-yellow: Protective earth (PE)
8 Cleaning
Important:
– Do not use aggressive cleaning agents, rubbing alcohol or other chemical solutions.
They damage the housing and can cause the product to malfunction.
– Do not immerse the product in water.
1. Disconnect the product from the power supply.
2. Let the product cool down to ambient temperature.
3. Clean the product with a dry, fibre-free cloth.
9 Disposal
This symbol must appear on any electrical and electronic equipment placed on
the EU market. This symbol indicates that this device should not be disposed of
as unsorted municipal waste at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose
of it separately from unsorted municipal waste. Spent batteries and accumulators,
which are not enclosed by the WEEE, as well as lamps that can be removed from
the WEEE in a non-destructive manner, must be removed by end users from the
WEEE in a non-destructive manner before it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-
back of waste. Conrad provides the following return options free of charge (more details on
our website):
in our Conrad offices
at the Conrad collection points
at the collection points of public waste management authorities or the collection points
set up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply
in countries outside of Germany.
4

10 Technical data

Item No.
2525889
Input voltage
Power consumption
Protection class
Ingress protection
Housing material
LED
Not replaceable
Dimmable
Colour temperature
Luminous flux
1800 lm
Colour rendering index
View angle
Operating temperature
Storage temperature
Dimensions (W x H x D)
121 x 44 x 102 mm 156 x 44 x 115 mm 190 x 44 x 128 mm
Weight
Item No.
Input voltage
Power consumption
Protection class
Ingress protection
Housing material
LED
Dimmable
Colour temperature
Luminous flux
Colour rendering index
View angle
Cable type
Cable length
Operating temperature
Storage temperature
Dimensions (W x H x D)
210 x 34.5 x 163.5 mm
Weight
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or the capture in
electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited.
This publication reflects the technical status at the time of printing.
Copyright by Conrad Electronic SE.
*2525889_2525885_2525886_2525887_2574213_V2_0922_jh_mh_en 18014399050091147-2 I3/O2 en
2525885
220 – 240 V/AC
20 W
30 W
I
IP65
Die-cast aluminium
28
42
Not replaceable
Not replaceable
No
3000 K
2350 lm
Ra > 80
120°
-35 to +45 °C
-40 to +45 °C
230 g
340 g
2525887
2574213
220 – 240 V/AC
100 W
200 W
I
IP65
Die-cast aluminium
112
Not replaceable
Not replaceable
No
3000 K
8500 lm
17000 lm
Ra > 80
120°
2
H05RN-F 3G1.0mm
20 cm
-35 to +45 °C
-40 to +45 °C
385 x 48 x 275 mm
680 g
2260 g
2525886
50 W
70
4600 lm
485 g
224