4. Power Meter Function
The power meter function is provided to monitor the condition of
the transmitter by measuring the relative
power being generated in the transmitter.
This meter will measure up to 10 or 100
Watt RF power, dependent of the position
of the sliding switch (4) [10W/100W].
5. Power Measurement
Do not turn on the transmitter, while the antenna and test meter
are disconnected.
> Connect the meter with the transmitter and the antenna in the
same way as for the SWR measurement.
> Place the sliding switch [PWR/SWR] (5) to PWR.
> For measuring of standard CB transmitter with 4 Watt RF power,
place the sliding switch (4) [10W/100W] to the 10W position.
> Turn the transmitter on and read the power from the upper scale
(WATT) (6). If the 100W range is used, the displayed power
value is to be multiplied by 10.
Unusual, high measured power, above the rated power of the
transmitter could indicate a faulty antenna system. Check all con-
nectors for unsatisfactory connection.

Specifications

range
Frequency Range
Impedance
dimensions
weight
1:1 bis 1:3
11-m Band
50 Ohm
85 x 58 x 78 mm
221 gr