Herunterladen Inhalt Inhalt Diese Seite drucken

Operation/Programming - DNT DoorAccess PRO Bedienungsanleitung

Fingerprint-türgriff
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5.7 Inserting the master fingerprint to add and delete users
Function

Operation/programming

Add User (Fingerprint/PIN)
Step 1: Read in master fingerprint
Step 2: Read user fingerprint three times* (or PIN – #)
(Step 2 can now be continued to add further users
Step 3: Read in master fingerprint
Delete User (Fingerprint/PIN)
Step 1: Read in master fingerprint twice within 5 s
Step 2: Read in user fingerprint* (or PIN – #)
(Step 2 can now be continued to add further users
Step 3: Read in master fingerprint
Please note that the master fingerprint can also be used to open the lock, but the programming
mode is also started. Therefore, the master fingerprint should not be used for normal opening.
5.8 Set the behaviour of the switching relay
This sets the active time or the behaviour of the switching relay.
Function
Operation/programming
Initiate programming
* – Master code – #
Set relay active time
3 – (1–99) – #
(pulse mode)
(relay remains energised for 1 to 99 s = door open,
factory setting: 5 s)
or
Set toggle mode
30 – #
(Switches the relay permanently to one position until the
input is made again, then the relay goes permanently to
the other position). This setting is used, for example, if a
door is to be freely traversable for a longer period of time.
Finish programming
*
5.9 Set access type
For multiple access attempts with the same fingerprints/PINs, a time of 5 seconds must not
be exceeded, otherwise the unit will return to standby mode without reacting.
Function
Operation/programming
Initiate programming
* – Master code – # (factory master code: 123456)
PIN access only
42 – #
or
Access by finger only
40 – #
print
or
Access only after
43 – (2–9) – #
Input (Fingerprint/
PIN) by several
users (2 to 9) higher
Safety)
or
Access for fingerprint
43 – # (factory setting)
print or PIN
Finish programming
*
5.10 Set displays/acknowledgement signal
Function
Initiate programming
Switch off acknowledgement tone
Switch on acknowledgement tone
or
Keypad illumination always off
Keypad illumination after
5 s automatically off
or
Fingerprint LED ring off
Fingerprint LED ring on
Finish programming
6. Operation
Door opening only with fingerprint
• Place registered finger
Open door only with PIN
• Enter registered PIN, confirm with #
Open door with multi-PIN/fingerprint
• Registered multi-access (2-9 users, see chapter) 5.9 hang up/enter
Open door with PIN or fingerprint
• Registered access (see chapter) 5.9 hang up/enter
Operation/programming
* – Master code – #
60 – #
61 – # (factory setting)
62 – #
63 – # (factory setting)
64 – #
65 – # (factory setting)
*