Transmitter Planar-D1

Technical data

40
Technical information
Frequency range
RF power
Typical working range
Frequency channel search, automatic
Antenna
Typical response time of the control
commands
Active/passive
LF modulation method
Data rate
Ø Current consumption
Prewarning time "Battery empty"
Serial number mode
(service case, device replacement)
LC/TFT display
Energy saving function (standby)
Machine data
Ambient operating temperature
Weight
Dimensions (L x W x H)
Case material
Status display
(7-segment, depending on the configuration)
Equipment safety
CE certification
Protection class
Data security
EMERGENCY STOP or STOP function
Power supply
Power supply
Operating time
Loading form
Charger available for (UE)
Plug form AC (adapter set)
Plug form DC
434.050 – 434.750 MHz
< 10 mW
≤ 100 m 
(depending on environmental conditions)
Integrated
approx. 50 ms
2 s
GFSK
9600 baud (bit / sec.)
approx. 60 mA
approx. 15 minutes
Input via key combination on the device
7-segment channel/status display
Standard: after 60 min.
Optional: Setting according to customer requirements
(continuous operation possible)
-20 °C up to +70 °C
160 g
124 mm x 56 mm x 37 mm
Impact resistant, glass fiber reinforced polyamide
1x (1-digit)
Yes
IP65
Addressing of each transmitter by unique bit combination
Yes (sending stop telegrams for 2 sec.)
2x AA/LR6/Mignon battery or accu
Up to 30 hours
Standard: Externally, via a separate charger
Option:
via wall mounted charging cradle
110 VAC – 230 VAC, 12/24 VDC
EU, USA, JP, GB, AU
Car charger plug
Planar-D1 / Compact-M2 R7