Herunterladen Inhalt Inhalt Diese Seite drucken

JL Audio XDM600/1 Bedienungsanleitung Seite 4

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

APPENDIX A:
Input Sensitivity Level Setting
Follow the steps below to adjust the input sensitivity of each amplifier
channel pair to achieve overall system balance.
Necessary Equipment
• Digital AC Voltmeter
• Sine-wave test tone recorded at 0 dBfs reference level in the frequency range to be amplified.
Do not use attenuated test tones (-10 dB, -20 dB, etc.).
Full range channel/amplifier applications: 1 kHz
Subwoofer channel/amplifier applications: 50 Hz
• Depending on your type of source unit, the sine-wave may be played via a CD, USB thumb drive, portable media player or
Bluetooth® audio source. Make sure to disable any EQ/DSP modes on your portable media player during level setting.
The Nine-Step Procedure
1. Disconnect the speaker(s) from the amplifier's speaker output connectors.
2. Turn off all processing (bass/treble, loudness, EQ, etc.) on the source unit, processors (if used) and amplifier.
Set the fader control to center position and the subwoofer level control to 3/4 of maximum, if used.
3. Turn the "Input Sens." control all the way down.
4. Set the source unit volume to 3/4 of full volume. This will allow for reasonable gain overlap with moderate clipping at full volume.
5. Using the chart below, determine the target voltage for input sensitivity adjustment according to the nominal impedance of the
speaker system connected to the amplifier outputs.
6. Verify that you have disconnected the speakers before proceeding. Play a track with an appropriate sine wave (within the
frequency range to be amplified) at 3/4 source unit volume.
7. Connect the AC voltmeter to the speaker output terminals of the amplifier.
Make sure to test the voltage at the correct terminals (+ and –).
8. Increase the "Input Sens." control until the target voltage is observed with the voltmeter.
9. Once you have adjusted each channel section to its maximum low-distortion output level, reconnect the speaker(s). The "Input
Sens." controls can now be adjusted downward if the amplifier requires attenuation to achieve the desired system balance.
IMPORTANT!
• Do not increase any "Input Sens." setting for any amplifier channel or channel pair in the system beyond the maximum level
established during this procedure. Doing so will result in audible distortion and possible speaker damage.
• It will be necessary to re-adjust the "Input Sens." if any equalizer boost is activated after setting the "Input Sens."
with this procedure. This applies to any EQ boost circuit, including source unit tone controls or EQ circuits. EQ cuts will not
require re-adjustment.
Nominal Impedance
6 | JL Audio® - XDM600/1
Target AC Voltage
40.0 V
38.7 V
34.6 V
not recommended
SPECIFICATIONS
Amplifier Section
Amplifier Topology
NexD™ Ultra-High Speed Class D
Power Supply Type
Unregulated MOSFET Switching
Minimum Copper
4 AWG
Power/GND Wire
(Note: CCA/Copper Clad Aluminum wire is not recommended.)
Recommended Fuse
50 A
Rated RMS Power @ 14.4V,
400W x 1 @ 4 Ω
<1% THD+N
Rated RMS Power @ 12.5V,
300W x 1 @ 4 Ω
<1% THD+N
Frequency Response
7 Hz – 500 Hz (+0, -1dB)
S/N Ratio
>83 dB (Referred to rated power),
(A-weighted, 20 Hz–20 kHz
>67 dB (Referred to 1 W)
noise bandwidth)
Damping Factor
>1000 / 50 Hz @ 4 Ω, >500 / 50 Hz @ 2 Ω
Input Section
Number of Inputs
2 (One Stereo Pair)
Input Type
Differential-Balanced with RCA jack inputs
Input Voltage Range
200mV – 4V RMS
Signal Processing
Filter Type
Active, 12dB or 24dB/octave Low-Pass, (50 – 500 Hz), defeatable
Remote Level Control
HD-RLC or MHD-RLC (optional). Full mute to 0 dB range.
Dimensions
L x W x H
8.52 in. x 7.09 in. x 2.05 in. (217 mm x 180 mm x 52 mm)
Due to ongoing product development, all specifications are subject to change without notice.
500W x 1 @ 3 Ω
600W x 1@ 2 Ω
400W x 1 @ 3 Ω
500W x 1@ 2 Ω
7