Herunterladen Inhalt Inhalt Diese Seite drucken

ELRO FCO240011 Anleitungshandbuch Seite 5

Co2-messgerät - luftqualitätsmessgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
9.
Carbon dioxide levels and guidelines
400PPM
400 ~ 1000PPM
>1000PPM
>1200PPM
>2000PPM
>5000PPM
10.
Maintenance
We recommend to manually test CO
cause of false alarms. Therefore, clean the CO
accumulated dust along the sides of the CO
Clean the device with a soft, damp and lint-free cloth. Make sure that no moisture enters the housing. Do not use any
sprays, solvents, alcohol-based cleaning agents or abrasive cleaners, but only clean water to moisten the cloth.
11.
Warnings
This manual contains important safety information about the CO
Read the manual carefully and keep it in a safe place for future reference.
Do not open the device in case it is damaged.
Do not remove any safety signs, stickers or labels from the device.
Keep all safety signs, stickers and labels legible condition.
This product cannot be used in factories, warehouses and other industrial environments that may be in high CO
concentration for a long time.
If the product is to be placed in a narrow space, the space should be well ventilated, especially the two diffusion
windows should be in a well-ventilated position.
The product should be away from heat source and avoid direct sunlight or other thermal radiation.
This product should not be used in the environment with high dust density for a long time.
12.
Specifications
Working voltage
CO
measurement range
2
CO
measurement error range
2
Pressure dependence
CO
measurement resolution and response time
2
Temperature range
Temperature measurement error range
Temperature measurement resolution/response time : 0.1.1°C /°F; T90 < 120sT90 < 120s
Humidity measurement resolution and response time : 0.1% ; T90 < 600s.1% ; T90 < 600s
Humidity measurement range
Humidity measurement error range
Backup battery running time
Work environment
Storage environment
Sensor service life
IP Rating
Environmental protection standard
Overall dimensions
Product weight
Normal outdoor air level
Typical level indoors with good ventilation.
NOTE: If CO
levels are low when building is sealed and occupied, check for overventilation (too
2
much fresh air = energy wasted).
ASHRAE and OSHA recommended maximum level in a closed room.
Considered maximum comfort level in many countries.
Poor air quality - requires ventilation.
According to many studies this level of CO
headache lower levels of concentration and increased likelihood of spreading respiratory viruses
like colds, etc.
OSHA and NIOSH first threshold for safety. Maximum allowed concentration within an 8
hour working period.
Monitor once a month by pressing and holding the test button. Dust is a major
2
Monitor. Never use a wet cloth or detergent to clean your CO
2
produces a significant increase in drowsiness, tiredness,
2
Monitor once a month. Use a vacuum cleaner to gently remove any
2
Monitor.
2
: DC5V (Power adapter 5V/1A)
: 400 ~ 5000 PPM
: ± (50ppm+ Read the numerical
: + 1.6 % reading per kPa deviation from normal pressure
: 1 PPM ; T90 < 120s
: -5°C ~ 50°C or 23°F ~ 122°F
: ± 0.5 or 0.9
: 0.0% ~ 99.9%RH
: ± 5% RH5% RH
: 12 Hours
: Working temperature -55°C ~ 50°C
: Working humidity 0 ~ 90% RH (no condensation)
: Storage temperature -10°C ~ 60°C
: Storage humidity 0 ~ 95% RH (no condensation)
: 10 years (End of product service life display "End")
: IP40
: RoHS
: 99 mm x 99 mm x 37 mm
: Net weight 291gr
- 5 -
Monitor.
2
2

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis