Herunterladen Inhalt Inhalt Diese Seite drucken

Mounting Location - Velleman PEM300D Bedienungsanleitung

Lichtschranke mit 2 strahlen, 60m
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

4. Mounting Location

Make sure there are no obstructions between the transmitter and the
receiver (trees, bushes, clotheslines etc.).
Avoid strong light (sun, car headlights, etc.) shining directly on
transmitter or receiver. When strong light stays in the optical axis for a
long time, it does not cause malfunction but will reduce the product life.
Do not install the units where they may be affected by dirty water or
direct sea spray.
Do not install the units on unsteady surfaces.
The receiver has to be placed within the detection range (30m/100ft)
and the spread of the beam (∅ 0.9m/3ft at 30m/100ft) of the
transmitter.
Install the sensors at a height of 0.8 to 1m (± 3ft), the ideal height to
capture human passers-by.
With the sensor block adjustments ([7] and [9] in the picture above), a
large variety of mounting combinations are possible. See "6. Alignment"
for guidelines.
5. Wiring / Contacts
Terminal connection 1 is the power 10 to 30V DC + line on both units.
Terminal connection 2 is the power 10 to 30V DC - line on both units.
The power lines need to be connected to these terminals.
Terminal connections 6 and 7 form a tamper output ; they are
connected through a dry contact relay.
When the cover is taken off, there is no contact.
No wires need to be connected to these terminals.
On the receiver, terminal 3 is normally connected to terminal 4 and in
the event of detection, contact with terminal 4 is broken and contact
with terminal 5 is established.
It depends on how your control panel works if you need to connect
either terminals 3 and 4 or terminals 3 and 5 to the control panel.
Maximum wiring distance
When two or more sets are connected, the maximum cable length is as
shown above divided by the number of sets.
Wire / size
AWG22
0.33mm²
AWG20
0.52mm²
AWG18
V. 02 – 27/11/2013
PEM300D
12V
m
320
ft
1050
m
550
ft
1800
m
800
Voltage
4
24V
2800
18000
4800
12750
7200
©Velleman nv