Do not use this heater with a programmable switch, timer or any automatic
switching device because of danger and/or fire hazard if the heater is covered
This infrared wall mounted heater is only suitable for mounting horizontally on a
solid vertical wall. Never install it vertically or on the ceiling as indicated in picture
2
The product must not be mounted on any inflammable surface such as wood or
plastic. Any inflammable materials must be at least 70 cm. away from the front
face. This is also the minimum distance the user has to keep from the product
because during use the front grille gets hot.
The appliance must not operate in rooms where danger can arise from explosive
gases or where inflammable materials are being used, such as wood block or
PVC flooring is being laid or sealed
Care should be taken to mount the appliance so that the product and the pull cord
switch are out of the reach of children. If it is installed in a bathroom, it should be
positioned so that it cannot be touched by anyone who is in the bath or in the
shower.
The safety zones defined by your local electrical installation Standards or the
Safety regulations applicable in your country are to be exactly observed. In any
case never install the heater inside the patterned areas called ZONE 0, 1 and 2
shown in picture 3.
After use we recommend to leave the product cool down for at least 10 – 15
minutes before touching it
Before the appliance is started up for the 1
used in the packaging or to protect the tube element have been removed
Installation. We recommend to switch off the mains electricity supply before
proceeding with the following steps.
Remove the front cover of the control unit by unscrewing the cross head screw on
the front (picture 4)
Prepare the 3 holes (diam. 5mm) in the wall respecting the distances shown in
picture 5. You can also use the control unit or the detachable frame from the box
as a reference. See picture 6.
Insert the 3 rawplugs you have found in the box.
Feed the electric lead in from behind through the round opening of the control unit
and make connections according to the following instructions (Picture 9).
Fasten the appliance to the wall using the supplied screws (picture 10);
This infrared quartz heater can be installed with the control unit on the right ( as
supplied) or on the left ( pictures 7 and 8). The product is pre-assembled to be
installed with the control unit on the right. If you want to turn it to the left you have
to:
Keep the product horizontally (do not pivot it!);
Remove the screw from the indicated position "1" (see pictures 7a and 7b);
Turn the heater and replace the screw in position "2" (see pictures 7c and 7d);
Change the switch cord pattern. The cord must always exit from the bottom of
the control unit (see pictures 7a and 7d).
st
time check that all the plastic pieces
Connection to the mains electricity supply
The appliance may only be connected to a 1/N/PE 230V AC 50 Hz supply with a
three core lead ( phase, neutral and earth wires). If the cordset is to be used we
recommend to use a rubber coated one (type H05-RRF) with at least a 3 x 1 mm2
section .
The safety precautions usual in the country of use and the regulations of the local
electricity supply are to be observed. The appliance is fitted in the factory with an
all – pole switch providing a contact break distance of ≥ 3 mm.
For the connection of the wires to the mains electricity supply the live phase
(brown color) is to be connected to the "L" marked pole, the neutral (blue color) to
the "N" pole and the earthing lead (yellow-green) to the specifically
marked pole
. (picture 9)
After having connected the product to the net is important to close the product
properly:
DO NOT pivot the product upwards;
BE SURE that the fixing screw of the front cover is on the top of the product
as shown in picture 4.
Operation
Pulling the switch the product gets in function. You can see from the front viewing
window the following symbols
Product rating
0
230V 1200W
OFF
230V 1500W
OFF
It is possible to swivel the housing downwards up to a maximum of 45° (picture 11)
Before doing this the appliance must be in 0 position (OFF) and must have cooled
down for at least 15 minutes.
This appliance complies with EEC directives 89/336 for Electromagnetic Compatibility
and 72/23 – 93/68 for Low Voltage Directive
I
II
600W
1200W
750W
1500W