Deckenheizelemente

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.6
VTD-UP room thermostat
The flush-mounted room thermostat is operated using mains
voltage. The switching capacity is 10 A or 2.3 kW.
Figure 13: VTD-UP
5
Mounting
5.1
Mounting the heating element
Notes on mounting:
The heating element must only be mounted on a level
surface, or the surface must be levelled as such that the
heating element can be fitted without mechanical
tension/twisting during installation.
The surface where the heating element is mounted
should have a permanent temperature resistance of
85°C.
Minimum distances between the heating element and
objects as well as surfaces in the room, such as the wall,
the floor, a couch or a cabinet, must be observed – as
described in chapter 5.1.1 Minimum distances on
page 27.
The heating element must never be covered with
insulation or similar material.
26
Figure 14: Circuit diagram VTD-UP with heating element
Crossbars, support beams and rafters must not be cut or
indented for the required ceiling opening and the
mounting of the heating element.
Heating elements of the VH-I series must be mounted at
a minimum distance of 180 cm from the floor.
Do not place the heating element in the vicinity of
combustible, highly flammable and/or easily melting
materials.
The load-bearing capacity of the ceiling construction
must be checked in advance. Classified sound/fire
protection requirements are not fulfilled by the heating
element.
Prior to mounting, check whether there are any
concealed installation lines.
www.vitramo.com
1722203