General safety precautions

Keep these instructions for future reference • Installa-
tion, electrical connections and adjustments must be
performed by qualified personnel in accordance with
Good Working Methods and in compliance with the
current standards • This product must only be used
for the specific purpose for which it was designed. Any
other use is to be considered improper and therefore
dangerous. The manufacturer cannot be held respon-
sible for any damage caused by improper, incorrect or
unreasonable use • Read the instructions carefully
before installing the product. Incorrect installation
may cause danger • Before installing the product,
make sure it is in perfect condition • Do not install
the product in explosive areas and atmospheres: the
presence of inflammable gas or fumes represents a
serious safety hazard • Danger of explosion if a bat-
tery is replaced with an incorrect type • The packag-
ing materials (plastic, polystyrene, etc.) should not
be discarded in the environment or left within reach
of children, as they are a potential source of danger.

1. Technical data

Degree of protection
IP43
Temperature
-20°C / +55°C
Supply voltage:
24 V
2. Installation
Properly fasten the COME function selector close to
the automation.
NOTE: the COME function selector can be wall re-
cessed on circular boxes, not supplied.

3. Electrical connections

Carry out the electrical connections as shown in fig. 2.
NOTE: use shielded cable for the electrical connections.
WARNING: in accordance with Directive 2004/108/EC, the
supplied ferrites must be installed as shown.
- Pass the cable through the ferrite, make 1 turn
and protect it from knocks by using heat-shrink
sheathing or similar. The ferrite must be secured to
the cable near the terminal boards (approximately
50 mm).
- Two COME function selectors can be connected to
one single automation, as shown in fig. 3.
- With one single COME function selector the same
function modes can be set in two different automa-
tions, by carrying out the electrical connections
shown in fig. 4.
- One or two COME function selectors can be con-
nected in order to set the same function modes up
to a maximum of four different automations (not
redundant type), as shown in fig. 5.
NOTE: for control panel networking, use the shielded
cable (not supplied) for data transmission, up to
1000 m total maximum length.
When COME function selector manages more than two
automations, cut the resistor
control panels (fig. 5).
- The outlet connecting the automation to the per-
in the intermediate
X
6
sonal computer, through the DMCS software, can
be accessed by removing the selector cover (fig. 1).
In order to monitor and operate the automation via
personal computer, follow the instructions in the
DMCS software operating handbook.
WARNING: if MD1 display modules are used, each MD1
display module must be configured separately with
each control panel before connecting to the network.
It is sufficient to supply each control panel for at least
30 s with its MD1 display module, then turn off the
supply, connect to the network and power all control
panels simultaneously.
3.1 Commands
Command
1
OP The closing of the contact opens the auto-
mation when the COME functions selector
switch is in any operating mode.
NOTE: if the operating mode selected is
stop, the OPEN command starts the
delayed night-time closure sequence.
1
KEY The opening of the contact deactivates the
functions selector switch.
WARNING: if an N.C. command is used,
remove the jumper [P].
RESET
Pressing the key eliminates the code set
in the functions selector switch.
3.2 Settings
OFF
Delayed night locking. 60
J1
s bi-directional sequence.
Emergency opening.
If the OPEN button is
held pressed, the COME
function selector is set
in the open door mode.
J2
NOTE: if the function
mode selected is stop,
the OPEN command
triggers the delayed
night locking.
J3 Access code disabled.
J4 DMCS jack disabled.
3.3 Signals
LED
Description
LED off
The COME function selector is working and no
access code is set.
LED on
The COME function selector is protected by an ac-
cess code. The COME function selector is disabled.
LED flashing
Setting or elimination of access code in pro-
gress. Start during the network acquisition
phase (for 30 s). The COME function selector or
another automation are not recognized by the
network (switch off and start again repeating
the learning phase).
Description
ON
Delayed night locking. 10
s bi-directional sequence.
Standard opening.
Impulse OPEN com-
mand.
Access code enabled.
DMCS jack enabled.