Herunterladen Inhalt Inhalt Diese Seite drucken

Device Use; Cleaning And Maintenance - incubato IN-36DDI Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für IN-36DDI:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
10
3.2. PREPARING FOR USE
APPLIANCE LOCATION
The temperature of environment must not be higher than
40°C and the relative humidity should be less than 85%.
Ensure good ventilation in the room in which the device
is being used. There should be at least 10 cm distance
between each side of the device and the wall or other
objects. The device should always be used when positioned
on an even, stable, clean, fireproof and dry surface, and
be out of the reach of children and persons with limited
mental and sensory functions. Position the device such that
you always have access to the power plug. The power cord
connected to the appliance must be properly grounded
and correspond to the technical details on the product
label!
ASSEMBLE THE DEVICE
1.
Install the rotating shaft as shown in the figure
below.
2.
Make sure that the protruding part of the shaft fits
into the handle of the egg tray.
3.
Plug the power cord into the socket on the device.

3.3. DEVICE USE

NOTE: Before placing eggs in the device, always make sure
that it is fully operational.
1.
Pour water into the container. Important! The water
level should be checked and topped up regularly.
EN
When hatching hen eggs, it is recommended to use the
amount of water in the container as per the following
instructions (preferably warm water):
a)
Day 1-7, pour water only into the middle groove of
the container;
b)
Day 8-14, pour water into the three central grooves
of the container;
c)
Day 15-21, fill the entire tank with water;
NOTE: The directions only apply to hatching hen eggs.
2.
Connect the device to a power source.
3.
Use the On/Off switch to turn the device on.
4.
An alarm will sound. Disable the alarm by pressing
a button on the control panel.
5.
The device will automatically rock the eggs every
2 hours. The eggs are rocked to the left and right,
up to 45 degrees for 10 seconds. Do not lift the
cover during automatic egg turning. Pay particular
attention when using the incubator for the first time..
To change the egg turning time, use the buttons (2)
and (3).
03.08.2021
6.
To restore factory values, press and hold the settings
button (4) and the value increase button (3).
7.
To test the rocking function, press and hold the LED
button (10) for approx. 3 seconds.
8.
Setting the temperature:
The egg incubator's temperature factory setting is
38°C.
Press the „Set" (6) button
Use buttons (2) and (3) to set the heating
temperature.
Press the „Set" (6) button to confirm the selection.
9.
Setting the alarm and limit values, calibrating the
thermometer:
Press and hold the „Set" button (6) for approx. 3
seconds.
Press the keys (2) and (3) until the temperature
display shows the symbol of the alarm / limit in
question as described in the table below.
Press the „Set" button (6) to enter the setting of the
alarm / limit value.
Use buttons (2) and (3) to set the preferred value.
NOTE: The device has a factory calibration value
(CA) set to 0. To check if the device shows correct
temperature, place an additional thermometer in
the device and observe the difference between its
reading and the indication on the device display.
Symbol on
Factory set
Description
the display
value
AL
Low temperature alarm
1°C (33.8°F)
AH
High temperature alarm
1°C (33.8°F)
CA
Thermometer calibration
0°C (32°F)
Setting the upper
39.5°C
HS
temperature limit
(103.1°F)
Setting the lower
LS
30°C (86°F)
temperature limit
10.
After entering the egg incubation settings, wait
about 20 minutes for the device to warm up and
reach the appropriate humidity.
11.
Place the eggs on the tray, keeping a distance of min.
2-3mm between the egg and the tray divider.
12.
To check the embryo's development status in the
egg, place the egg on the ovoscope (11), and switch
on the LED with the button (10).
03.08.2021
EN
Tips for incubating eggs:
Before incubating eggs, always check that the
incubator is in operational condition and its
functions are working correctly.
For best results, it's better to choose medium- or
small-sized eggs for hatching. Fertilized eggs for
incubation should be fresh and cleaned of impurities
on the shell.
The proper method of placing eggs for hatching is
to arrange them with the wider end upwards and
the narrower end downwards, as shown in the figure
below.
To avoid hitting the egg with the lid, place large eggs
in the middle of the tray and smaller ones on the
sides. Always check that the egg is not too large to
avoid accidental damage.
If the eggs are too large to place on the tray, it is
recommended to remove the trays and arrange the
fertilised eggs directly on the white grid.
The water level in the incubator should be constantly
monitored to ensure adequate humidity for hatching
eggs.
If the ambient temperature drops below 20 °C, we
recommend placing the incubator in a unit made of
insulating material, e.g. polystyrene foam, etc. If such
insulation is not possible, it is recommended to place
the incubator in a heated room or surround it with
thick material such as blankets.
After 19 days of incubation, when the egg shells start
to crack, it is recommended to remove the eggs from
the egg tray and place them on a white grid to hatch
the chicks.
It often happens that some eggs do not completely
hatch after 19 days, then you should wait another
2-3 days.
When a chick gets stuck in the shell, spray the shell
with warm water and help by gently pulling off the
egg shell.
After hatching, the chicks should be kept in a warm
place and supplied with proper food and water.
Do not test eggs with the ovoscope for the first 4
days to avoid a sharp drop in temperature, which
may adversely affect the development of the
embryo.
The first ovoscope examination is recommended
after 5-6 days to separate unfertilized eggs and eggs
with dead embryos.

3.4. CLEANING AND MAINTENANCE

a)
Always unplug the device before cleaning it.
b)
Use only non-corrosive cleaners to clean the surface.
c)
After cleaning the device, all parts should be dried
completely before using it again.
d)
Store the unit in a dry, cool place, free from moisture
and direct exposure to sunlight.
e)
Do not spray the device with a water jet or submerge
it in water.
f)
Do not allow water to get inside the device through
vents in the housing of the device.
g)
Clean the vents with a brush and compressed air.
11

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis