Herunterladen Inhalt Inhalt Diese Seite drucken

JCT JES-360Ex Bedienungsanleitung Seite 34

Beheizte gasentnahmesonde
Inhaltsverzeichnis

Werbung

Manual
JES-360Ex
BA_DE_JES360Ex_v1.04
–––––––––––––––
[ 34 / 40 ]
UNCERTIFIED TRANSLATION
Physikalisch-Technische Bundesanstalt
Braunschweig and Berlin
S C H E D U L E
(13)
EC-Type Examination Certificate PTB 99 ATEX 3103
(14)
(15) Description of the equipment
Junction and terminal boxes of polyester resin with a surface resistance ≥ 1 GΩ, Type series
8118/...-..., for fixed installation, with built-in - separately certified - line-up or hood-type
terminals for non-intrinsically safe or - separately certified - intrinsically safe circuits.
Marking of explosion protection
Fitting with terminals
only for non-intrinsically safe circuits
-
only for intrinsically safe circuits
-
only for intrinsically safe circuits
-
Technical data
Rated voltage:
Rated current, number of conductors and conductor cross section are determined in the
associated additional sheets.
Ambient temperature range, max.:
Contact, foreign particles and water protection
Note
The degree of protection - at least IP 54 - is achieved only when the tested gaskets, cable
glands and stopping plugs are used properly.
Instruction of the manufacturer "Clean only with wet cloth" is to be followed.
The suitability for low ambient temperatures is visible by special marking. Only such separately
certified sealing gaskets and built-in and built-on components, which are suitable for these
temperatures, are used. Additional instructions of the manufacturer are to be followed.
(16) Test report
PTB Ex 99-30041 (consisting of 6 pages, description and 2 drawings)
(17) Special requirements
(18) Essential health and safety requirements
Zertifizierungsstelle Explosionsschutz
By order:
signed: U. Engel
L.S.
Dr.-Ing. U. Engel
Regierungsdirektor
EC-type-examination Certificates without signature and official stamp shall not be valid. The certificates may be circulated
only without alteration. Extracts or alterations are subject to approval by the Physikalisch-Technische Bundesanstalt.
In case of dispute, the German text shall prevail.
Physikalisch-Technische Bundesanstalt Bundesallee 100 D-38116 Braunschweig
–––––––––––––––––
EEx e II T6 or T5 for T
≤ + 55 °C
amb
EEx ia/ib IIC/IIB /IIA T6
≤ +55 °C
EEx ia/ib IIC/IIB /IIA T5 for T
amb
max. 1100 V
(depending on the operating voltage range
of the terminals used)
-50 °C ≤ T ≤ +55 °C
min. IP 54 to EN 60 529: 1991
not applicable
covered by standards
Braunschweig, 19 April 1999