VDC voltage too low protection
Input current over high protection.
IPM module thermal circuit is
abnormal
IPM module temperature too high
protection
PFC module protection
DC fan motor failure
PFC module thermal circuit is
abnormal
PFC module high temperature
protection
Input power failure
4. Compressor or driver board
damaged
EE12
1. Mother line voltage is too low
2. Driver board is damaged.
EE13
1. The compressor current is too
large momentary
2. The water flow is abnormal
3. Power fluctuations within a short
time
4. Wrong PFC inductor
1. Output enormity of IPM module
thermal circuit
EE14
2. Fan motor is abnormal or damaged
Fan blade is broken
1. Output exception of IPM module
thermal circuit
EE15
2. Motor is abnormal or damaged
3. Fan blade is broken
1. Output exception of PFC module
2. Motor is abnormal or damaged
3. Fan blade is broken
EE16
4. Input voltage leap, input power is
abnormal
1. DC motor is damaged
2. Main board is damaged
EE17
3. The fan blade is stuck
EE18
The driver board is damaged
1. PFC module thermal circuit output
abnormal
2. Motor is abnormal or damaged
EE19
3. Fan blade is broken
4. The screw in the driver board is not
tight
The supply voltage fluctuates too
EE20
much
61
1. Check if the power is in the normal
range
2. Change driver board
1. Check the compressor
2. Check the waterway system
3. Check if the power is in the normal
range
4. Check if the correct PFC inductor is
used
1. Change a driver board
2. Check if the motor speed is too
low or fan motor damaged, change
another one
3. Change another fan blade
1. Change a driver board
2. Check if the fan motor speed is too
low or fan motor damaged, change
another one
3. Change another fan blade
1. Change a driver board
2. Check if the motor speed is too
low or fan motor damaged, change
another one
3. Change another fan blade
4. Check the input voltage
1. Detect DC motor, replace with a
new one
2. Change a new main board
3. Find out the barrier and work it
out
1. Change a new driver board
2. Check if the fan motor speed is too
low or fan motor damaged, change
another one
1. Change a new driver board
2. Check if the motor speed is too
low or fan motor damaged, change
another one
3. Change another fan blade
4. Check if the screw is loose
Check whether the voltage is stable