Herunterladen Inhalt Inhalt Diese Seite drucken

Before Installation / Placement Into Service; Important Safety Instructions; Cooling System - Safety Instructions; Water Circuit - Safety Instructions - A.O. Smith AH-290 Installations-, Benutzer- Und Wartungsanleitung

Luft / wasser wärmepumpe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2.
Before Installation /
Placement into
service
44
2.1

Important safety instructions

In the design and implementation of the heat pump, all relevant EU
guidelines have been adhered to.
Work on the heat pump may only be performed by trained
personnel! Take all necessary precautions in order to avoid
accidents while working!
2.1.1 Cooling system – safety instructions
The trained repairman must see to it that parts containing the refrigerant
are emptied to a level at which the execution of the work can occur in a
responsible manner without any dangers, before the commencement of
repairs and service work.
When repairing and servicing the heat pump with the refrigerant system
opened, and particularly for work with an open flame (soldering, welding,
etc.), precautions must be taken to prevent fires from starting.
2.1.2 Electrical circuit – safety instructions
When working on the heat pump, the main supply must
always be disconnected – pull the plug out!
When connecting the heat pump to the power supply, the local and national
rules and norms must be adhered to. In addition, regard must be paid to
possible requirements posed by the energy supplier.
2.1.3 Water circuit – safety instructions
Only drinking water quality water may be used. During installation, regard
must be paid to the choice of materials and it must be ensured that they can
work together without problems in the entire circuit.
Special attention must be paid when using galvanized
components and components containing aluminum!
Safety equipment must be installed to prevent over pressure in the
system.
All pipe work must comply with water safety regulations.
2.2

Delivery

The heat pump is delivered without water, condense water tube and the
safety equipment for the water circuit.
2.3

Storage

The heat pump must be stored upright without water and in its packaging.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis