Herunterladen Inhalt Inhalt Diese Seite drucken

Overload Protection; Technical Data - Sygonix 2377796 Bedienungsanleitung

Mehrfachsteckdosen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7.2 Overload protection

Only available for the following: Item no. 2377805, 2377806, 2377807, 2377808
Protects against overcurrent that can cause overheating.
When triggered the power supply to the sockets will be interrupted.
Preconditions:
a
Overload protection has been triggered.
1. Switch the main power switch OFF (position "O").
2. Eliminate the condition(s) triggering the protection.
3. Wait approximately 5 – 10 minutes to allow the product to cool down.
4. Briefly press the reset button.
5. Switch the main power switch ON (position "I").
à
The product should be ready for use again.
8 Protection (USB ports)
8.1 Overload protection
Protects against overcurrent that can cause overheating.
When triggered the power supply to the port(s) will be interrupted.
The power supply will resume when the condition(s) triggering the protection are re-
moved.
9 Cleaning and care
Important:
– Do not use aggressive cleaning agents, rubbing alcohol or other chemical solutions.
They damage the housing and can cause the product to malfunction.
– Do not immerse the product in water.
1. Disconnect the product from the power supply.
2. Clean the product with a dry, fibre-free cloth.
10 Disposal
This symbol must appear on any electrical and electronic equipment placed on
the EU market. This symbol indicates that this device should not be disposed of
as unsorted municipal waste at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose
of it separately from unsorted municipal waste. Spent batteries and accumulators,
which are not enclosed by the WEEE, as well as lamps that can be removed from
the WEEE in a non-destructive manner, must be removed by end users from the
WEEE in a non-destructive manner before it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-
back of waste. Conrad provides the following return options free of charge (more details on
our website):
in our Conrad offices
at the Conrad collection points
at the collection points of public waste management authorities or the collection points
set up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply
in countries outside of Germany.

11 Technical data

11.1 General
Rated input ..................................... 230 V/AC, 50 Hz, 16 A
Rated power ................................... max. 3680 W
Cable type ...................................... H05VV-F 3G1.5 mm²
Cable length ................................... 1.4 m
Enhanced protection against acci-
dental contact ................................. Yes
Protection (mains sockets) ............. SPD (surge protection device): Type 3 Uc 255 V/AC
Protection (USB ports).................... Overload
Cable management ........................ yes
Mounting possible........................... yes
Operating conditions....................... -5 to +40 °C, <85 % RH (non-condensing)
Storage conditions.......................... -5 to +40 °C, <85 % RH (non-condensing)
4
(leakage current 12 kA)
Overload protection (only available for the following:
Item no. 2377805, 2377806, 2377807, 2377808)
11.2 Model specific
Item no.:
Consumers
2377796
4x mains, 2x USB-A
2377802
6x mains, 2x USB-A
2377803
8x mains, 2x USB-A
2377804
10x mains, 2x USB-A
2377805
4x mains
2377806
6x mains
2377807
8x mains
2377808
10x mains
11.3 Data according to EU regulation 2019/1782
Item No.
2377796
2377802
2377803
2377804
Manufacturer
Commercial registration number
Model identifier
Input voltage
Input AC frequency
Output voltage
Output current
Output power
Average active efficiency
Efficiency at low load (10 %)
No-load power consumption
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or the capture in
electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited.
This publication reflects the technical status at the time of printing.
Copyright by Conrad Electronic SE.
*2368895_V4_0722_dh_mh_en 27021598012639371-2 I4/O4 en
Dimensions
(L x W x H)
440 x 74 x 47 mm
526 x 74 x 47 mm
612 x 74 x 47 mm
698 x 74 x 47 mm
415 x 74 x 47 mm
501 x 74 x 47mm
587 x 74 x 47 mm
673 x 74 x 47 mm
Model Identifier
GES-243
GES-245
GES-246
GES-247
Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau
HRB 3896
GES-243, GES-245, GES-246, GES-247
230 V/AC
50/60 Hz
USB-A 1: 5.0 V/DC, 2.4 A, 12.0 W
USB-A 2: 5.0 V/DC, 2.4 A, 12.0 W
USB-A 1 + USB-A 2: 5 V/DC, 2.4 A, 12.0 W
80.1 %
77.6 %
0.08 W
Weight
648 g
739 g
837 g
929 g
609 g
735 g
809 g
904 g

Werbung