7. PROBLEM SHOOTING
SYMPTOM
The unit is not
Check if the water level indicator
operating.
There is little
Check if the room temperature is
formation of
condensate.
Water Leakage
Excessive Noise
E2
Display when Room temperature
CL
Display when Room temperature
Error
CH
code
LO
HI
INSPECTION
Check the power connection in
securely.
lights up?
Check the room temperature.
Check the air filter for dirt.
Check if the air duct is blocked.
below 20℃.
Set humidity level is higher than
currentHumidity value.
Overflow while moving the unit.
Check if the drain hose is kinked
or bends.
Check if the unit is securely
positioned.
Check if any loose, vibrating
parts.
Noise sounds like water flowing.
Humidity sensor dampened or
failure.
is below 5°C(41°F).
is above38℃(100°F).
Display when Room relative
humidity is bellow 20%RH.
Display when Room relative
humidity is above 90%RH.
Insert the power cord securely
Empty the water tank and
The range of operating
Clean the air filter as necessary.
To clear the obstacle.
This is normal. Low humidity in
low temperature environment.
Set the humidity level below
Empty the water tank before
Straighten the hose to avoid a
Place the unit on horizontal
Secure and tight the parts.
Noise comes from flowing
refrigerant. This is normal.
To clean or replace the
Normal. The compressor stops,
and the fan keeps running.
Normal. The compressor stops,
and the fan keeps running.
Normal. The compressor stops,
and the fan keeps running.
Normal. The compressor and
17 17
SOLUTION
into the wallOutlet.
reinstall correctly.
temperature is 5-38℃.
current humidity value.
transport.
trap existing.
and firm ground.
humidity sensor.
the fan keep running.