Safety rules

• The plant operator must put in place suitable technical
safety measures to ensure that the operating parame-
ters cannot be exceeded.
• The personnel carrying out the installation, commis-
sioning, maintenance or repair of the device must be
properly qualified for this type of work. In particular,
the persons concerned must
- be suitably trained and familiar with handling
compressed-air systems besides being informed
about the associated dangers,
- know the content of the relevant instructions for
installation and operation, and
- possess vocational qualifications or entitlements
in this particular field of work.
• Before the start of any work, the housing must first be
depressurized.
• In the case of CLEARPOINT
filters with BEKOMAT
separate instructions need to be complied with.
• To ensure safe functioning, only use the device within
the operational limits (operating pressure, operating
temperature, volumetric flow, material stability). Pres-
sure surges must be avoided.
• Where a BEKOMAT
be ensured that the device is designed for the stated
volumetric flow of compressed air or gas. Condensate
surges into the device can impair the function.
• In the event of leaks, shut off the compressed-air
supply immediately and eliminate the cause in order
to maintain safe and cost-effective operation.
• CLEARPOINT
water separators and filters, includ-
®
ing accessories, must be checked once a week. This
applies in particular to the function of the separator.
When using water separators/filters with a manual
drain: be careful opening the ball valve (large opening
cross-section). Manual drains must be secured against
accidental opening.
• For connections or joints only use suitably threaded
fittings designed for this pressure range. (see page
18)
• CLEARPOINT
wall brackets are designed for a
®
maximum load of 3 filters in series. Any additional me-
chanical loads, e.g. due to pipes or other equipment,
must be avoided.
CLEARPOINT S040 - M023 HP 50
water separators and
®
12 PN 63 all the rules of the
®
12 PN 63 is installed, it must
®
english
Areas of application of water separators
CLEARPOINT
water separators are designed for the
®
separation of solid particles and liquid droplets from non-
aggressive compressed air or industrial gases.
Limits in usage
max. operating pressure :
max. operating temperature : +2 °C to +60 °C
Areas of application of filter
CLEARPOINT
filters are designed for the separation
®
of solid particles, aerosols, oil vapours and odours from
non-aggressive compressed air or industrial gases. De-
pending on the specific application, the filter housings
are provided with different inserts:
CX Coarse filter for the separation of coarse solid matter
pollutants up to 25 µm.
FX Fine filter element for the separation of liquids up to
0.05 mg/m³ and solid particles up to 1 µm.
SX Super fine filter element for the separation of liquids
up to 0.005 mg/m³ and solid particles up to 0.01 µm.
A Activated carbon filter elements for the separation
of oil vapours up to 0.003 mg/m³ and odours .
R(x) Dust filter for the separation of solid particles,
fineness from C to S
Max. operating pressure:
Max. operating temperature:
Recommended operating temperature:
CX, FX, SX:
A:
R(x):
50 bar(g)
to 50 bar(g)
+2 °C to +60 °C
+2 °C ... +40 °C
+2 °C ... +30 °C
+2 °C ... +60 °C
7