AXIS Ex Series
1. Remove the two locking grub screws. Use the included stainless steel bits.
2. Remove the threaded chamber cover. To avoid damaging the threads, use the included
removal tool.
3. Route the cables through threaded entry points and suitably certified glands.
WARNING
Earthing connection must be minimum 14 AWG (2 mm²) conductor with green and yellow
insulation. Connect through the M4 earth stud using the supplied crimp ring terminal.
Tighten with a 7 mm ring spanner or socket.
The terminal plugs can be disconnected to allow easy termination outside of the enclosure. For
TB1 and TB2 use wire between 18 - 12 AWG (0.8 - 3.0 mm²).
WARNING
Only one wire should be connected to each clamping point.
An external earth connection point is available for up to 11 AWG (4 mm²) connection. When
used, it shall be used with a crimp ring terminal.
Use an RJ45 connector (CAT5 or higher) for network connection. Optionally, an SFP slot is available
for an additional network connection, this port utilizes various SFP modules including fibre optic.
WARNING
The use of a fiber optic cable and internal connections shall comply with requirements
of UL/IEC/EN 60079-14.
When wiring is completed, fasten the threaded chamber cover and tighten until the joint is closed.
Tighten the two locking grub screws. Use the included stainless steel bits.