Herunterladen Diese Seite drucken

Only For In-Line Installation: - Olymp LavaSeat VAREO Edition Montageanleitung

Bodenmontage und reiheninstallation

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mounting instructions for installers
Important: Read these instructions thoroughly before
installing the appliance. Determine the precise position in
the salon with the salon owner and the installation
specialist.
The wash unit is intended for operation in clean and
dry rooms at normal room temperature.
In the water supply system only original components
supplied by the manufacturer must be used.
The wash unit must only be connected to a water
supply where the supply pressure does not exceed
20 bar (20 MP a).
The new set of hoses supplied with the unit must be
used. Old hoses must not be used.
1.
The water supply pipes to the wash unit must be
equipped with an "Aqua-Stop" system.
2.
Place the mounting template at the determined
position and use it to drill the required holes.
Observe the notes on the mounting template!
3.
Make the holes for cold water (K), hot water (W)
and waste water (A).
4.
Route ½" pipes for the hot and cold water supply
and 40 mm dia. drain pipe with connecting sleeve for
the siphon through the floor.
5.
Ensure that the stop valves and siphon are at the
correct position and correctly spaced (see the
mounting template).
6.
Height of the connecting pipes and drain pipe:
½" pipe: 50 mm above finished floor 40 mm dia. drain
pipe: 50 mm above finished floor
Mounting instructions for appliance fitters
7.
Detach the backrest cushion (1):
Pull the backrest upwards and remove. On the vibro-
massage model, disconnect the 4 cables from
the adapter cables which lead to the control box.
8.
Detach the seat body (2):
Only slacken the 4 wing screws (3) underneath the
seat. Remove the 2 hexagon socket bolts (4)
(connection between seat and frame).
Detach the element connecting the seat to the leg
rest (6).
Pull the seat together with the armrests upwards
and remove

8.1 Only for in-line installation:

Prepare the cover sections (7) for connection of the
installation tunnel (Fig. 2):
Cut out a 140 mm dia. section as shown in the
illustration.
Make sure that the mounting side corresponds to
that shown in the installation diagram.
Vareo MO B+R
All manuals and user guides at all-guides.com
GB
Mounting instructions for appliance fitters
9.
Align the substructure (9) according to the
installation template and secure to the floor.
6 anchor bolts M 10 x 125 (extending 30 mm above the
finished floor) or metal plugs with metric thread for
hexagonal screws M 10 x 60.
9.1 Only for in-line installation:
Secure the side cover sections (7) to the tunnel side
of the units using Velcro tape.
Attach 2 mounting brackets for the installation tunnel
to each of these side sections (Fig. 2).
Caution:
Attach brackets inside the installation tunnel!
Tunnel ends must be protected with edge covers!
Mount lower part of tunnel.
Clip in upper part of tunnel.
Mounting instructions for installers
10. Make sure that pipes/pressure hoses and drain hose are
parallel. Connect the unit. Prevent the stop valves
from turning while they are being screwed on.
Connect the waste water hose to the siphon using a
seal and union nut. Insert the waste water hose at least
3 to 4 cm into the siphon. Connect the drain bushing to
the waste water hose using a hose clamp.
11. Close the mixing tap. Open the stop valve and check
for leaks with the mixing tap closed. Check the mixed
water. The hot water and cold water supply must
correspond to the coloured symbols on the mixing tap.
12.
Check the pressure of the unit with 8 bar water
pressure. Then set the pressure to 3 to 5 bar. On
completion of the installation work, always rinse out the
water pipes. A central regulating tap is required if more
than one unit is installed. This tap must be easily
accessible from the salon.
These mounting instructions apply to the connection
of one unit. If more than one unit is to be installed, the pipe
cross section must be increased
accordingly.
Important: If the water pressure is above 5 bar, it must be
regulated by a pressure reduction valve. Since a pressure
reduction valve is used for boilers, such a valve can be fitted
along the common water
supply line.
Note for salon owners:
The connections described under points 1 to 5 and 9 to 11
must be performed by the installer. The installer is
responsible for any problems that may occur. The
manufacturer of the unit shall not accept warranty claims for
this work.