5.0 Certification/approvals
IECEx units
Ex d unit (IEC certification No. IECEx BAS 10.0086X)
10J:- Ex d IIB T4 (-55°C to +65°C) Gb
15J:- Ex d IIB T4 (-55°C to +50°C) Gb
Ex de unit (IEC certification No. IECEx BAS 10.0087X)
10J: Ex db eb IIB T4 (-50°C to +65°C) Gb
15J: Ex db eb IIB T4 (-50°C to +50°C) Gb
The IECEx certificate and product label carry the IECEx
equipment protection level marking
Gb
Where Gb signifies suitability for use in a Zone 1 surface
industries area in the presence of gas.
ATEX units
Ex d unit (ATEX certification No. BAS00ATEX2204X)
10J:- Ex d IIB T4 (-55°C to +65°C) Gb
15J:- Ex d IIB T4 (-55°C to +50°C) Gb
Ex de unit (ATEX certification No. BAS00ATEX2226X)
10J: Ex db eb IIB T4 (-50°C to +65°C) Gb
15J: Ex db eb IIB T4 (-50°C to +50°C) Gb
The ATEX certificate and product label carry the ATEX
group and category marking:
II 2 G
Where:
Signifies compliance with ATEX
II
Signifies suitability for use in surface industries
2
Signifies suitability for use in a zone 1 area
G
Signifies suitability for use in the presence of gases

6.0 Special conditions for safe use

A. Exd units: Certificates BAS00ATEX2204X & IECEx
BAS 10.0086X
I.
The mating thread of any cable entry device unused
with this apparatus must exceed 12mm in length.
II.
Painting and surface finishes, other than those
applied by the manufacturer, are not permitted.
B. Exde units: Certificates BAS00ATEX2226X & IECEx
BAS 10.0087X
I.
Not more than one single or multiple strand lead shall
be connected into either side of any terminal, unless
multiple connectors have been joined in a suitable
manner, e.g. two conductors into a single insulated
crimped boot lace ferrule.
II.
Leads connected to the terminal shall be insulated
for the appropriate voltage and this insulation shall
extend to within 1mm of the metal of the terminal
throat.
III. All terminal screws, used and unused, shall be fully
tightened down.
IV. Minimum creepage and clearance distances between
the terminals and adjacent conductive parts (including
cable entry devices) must be at least 5mm.
V.
Painting and surface finishes, other than those
applied by the manufacturer, are not permitted.
These units also have the following approvals
Main Harmonics (AC) to EN61000-6-3:2007/
IEC61000-3-2:2006
Conducted Emissions (DC) to EN61000-6-3:2007
Radiated Field Immunity (DC and AC) to EN61000-6-
2:2005/IEC61000-4-3:2002 + A1:2002
Electrical Fast Transients/Bursts (DC and AC) to
EN61000-6-2:2005/IEC61000-4-4:2004
Dips and Interruptions (AC) to EN61000-6-2:2005/
IEC61000-4-11:2004
Ingress protection IP66 to BS EN 60529:1992
Ingress protection IP67 to BS EN 60529:2001