Provide ample ventilation. This gas appliance consumes air (oxygen). Do not use this appliance in an unventilated space to
avoid endangering your life. If still more gas appliances and/or occupants using gas are added to the space, additional ventilation
Read these instructions carefully so as to familiarise yourself with the appliance before fiting the appliance to a gas cylinder.
1. General
• This appliance complies with BS EN 498:2012, EN 484:2019.
• This appliance may only be used with an approved hose and regulator
• The gas cylinder is to be used in the upright position.
• Only to be used with a gas cylinder that does not exceed 500mm in height(Regulator is included) and 400 mm in width.
• Gas appliances require ventilation for efficient performance and to ensure the safety of users and other persons in close proximity.
• Warning: Accessible parts may be very hot. Keep young children away.
• After use, turn off the gas supply at the cylinder, and then at the control knobs.
• Use outdoors only!
Gas Supply Sources
AE = United Arab Emirates
CZ = Czech Republic
FR = France
JP = Japan
PT = Portugal
SK = Slovakia
For gas category I3B/P(50)
Meridian 3 Built-in, 982231, total heat input: 9.6kW/Butane 699g/h
Meridian 4 Built-in, 982241, total heat input: 12.4kW/Butane 944g/h
must be provided.
IMPORTANT
Retain these instructions for future reference.
Country of Use
Appliance Catagories
Allowable gasses
Main 3 Burner BBQ Unit
Jet Number
Nominal Usage
Gross nom. heat input
Main 4 Burner BBQ Unit
Jet Number
Nominal Usage
Gross nom. heat input
An approved hose and regulator connected to a refillable gas container not exceeding 9kg and
Country Name and Abbreviations
AL = Albania
AT = Austria
DE = Germany
DK = Denmark
GB = United Kingdom
GR = Greece
KR = Korea
NL = Netherlands
RO = Romania
RU = Russia
SE = Sweden
TR = Turkey
CAUTION
DE, AT
I
3B/P (50)
Butane @ 50mBar
Propane @ 50mBar
Butane/Propane mixtures
@ 50mBar
0.78
Butane - 233 g/h
per burner
3.2 kW per burner
(3.2 kW x 3 = 9.6 kW in total)
0.78
Butane - 236 g/h
per burner
3.1 kW per burne
(3.1 kW x 4 = 12.4 kW in
total)
complying with local regulation in force
BE = Belgium
ES = Spain
HR = Croatia
NO = Norway
RS = Serbia
ZA = South Africa
1 1
GB
CH = Switzerland
FI = Finland
IT = Italy
PL = Poland
SI = Slovenia