Herunterladen Inhalt Inhalt Diese Seite drucken

Installation In Ducted Configuration (2 Ducts) - Windhager AquaWIN Air 273 Montage- Und Bedienungsanleitung

Brauchwasser-wärmepumpe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Overview

3. Installation in ducted configuration (2 ducts).

Location is at least frost-free (T > 1°C).
"Ducting" setting to be set to "Exterior/Exterior"
Recommended location: living space (the thermal losses of the water
heater are not lost), near the outer walls. Avoid placing the water heater
and/or the ducts close to bedrooms for sound comfort.
Examples of locations:
• Laundry room,
• Cellar,
• Entry hall cupboard.
100mm
mini
670mm
mini
Respect the maximum lengths of ducting. Use rigid or semi-rigid insulated ducts. Provide grills on
the air inlet and output to avoid and foreign objects entering. Attention, air inlet and outlet grills
which can be manually obstructed are forbidden
Leave a space of 500mm in front of the electrical equipment and 300mm in front of the hydraulic
equipment so that the water heater is accessible for its periodic servicing.
132
Installation
Use
Maintenance
Warranty
Exterior/Exterior

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Aquawin air 203

Inhaltsverzeichnis