Herunterladen Inhalt Inhalt Diese Seite drucken

EINHELL GE-AW 1144 SMART Originalbetriebsanleitung Seite 26

Hauswasserautomat
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Faults
Insuffi cient
The intake line has a leak or
pumping rate
is damaged
Intake height too high.
The intake cage (incl. the
non-return valve) is soiled.
The coarse fi lter (incl. the
non-return valve) is soiled.
The hose on the discharge
side is kinked.
The cross-section on the
discharge side becomes
narrower.
The pump's delivery rate
depends on the delivery
head and on the connected
peripherals.
The motor
No power available.
does not start
The impeller is blocked.
The thermostat
Overheating / overloading of
switches off
the pump
the pump
The temperature of the
pumped medium or the en-
vironment is too high.
Dry-running of the pump.
Anl_GE_AW_1144_SMART_SPK13.indb 26
Anl_GE_AW_1144_SMART_SPK13.indb 26
GB
Possible cause
Check the following points for leaks:
- Intake line
- Water fi lling screw / water drain screw / ventilation
- Connection points of the intake line
Check the intake height.
Clean the intake cage (incl. the non-return valve).
Clean the coarse fi lter (incl. the non-return valve).
Remove any kinks in the hose.
Avoid narrow points.
Take account of the maximum delivery head, change
the hose diameter or hose length if necessary.
Check the fuses and the electrical connection.
Use a screwdriver to turn the motor shaft through the
fan hood (release the stuck mechanical seal).
Let the equipment cool down!
Take account of the permitted temperature of the
pumped medium.
Ensure that the pump is provided with adequate
cooling.
Eliminate the cause of the dry-running.
Note the points under "Pump fails to prime".
Prevent dry-running.
- 26 -
Remedy
screw / coarse fi lter cap
10.01.2022 09:16:32
10.01.2022 09:16:32

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

41.803.80