NOTE!
The pipe must always be installed vertically above the
roof and extend at least 600 mm above the roof surface.
If the outlet air pipe is to be enclosed (e.g. using metal
siding), make sure that the end of the pipe extends at
least 400 mm above the enclosure.
If installed where snow is likely to accumulate it might
be necessary to extend the pipe further, and to secure
accordingly.
2.5.2 INLET AIR TERMINAL
It is required to have an inlet air vent in accordance with manufacturer specifications, this to ensure adequate air
circulation and oxygen required for proper incineration. T
specially designed air vent designed for optimal flow and increased product efficiency.
preferably be installed as close to the Cinderella toilet as possible, to ensure a good air supply to the toilet and reduce
the environmental impact in the toilet room. It is important that there are no other air-dependent installations used
at the same time as the toilet, e.g. an extractor fan or fireplace. The Cinderella Classic toilet draws air mainly from the
underside of the toilet. It is therefore possible to have the air intake underneath the toilet. This allows you to insulate
the air as much as possible in the toilet and minimise the environmental impact in the toilet room.
NOTE!
10
The inlet vent's minimum dimensions must be 160 mm (diameter) / 201 cm²
The vent must be open at all times when using the appliance. Remember to clean the
vent at regular intervals.
Make sure that there is no conflict between the toilet's air supply and other installa-
tions, such as a fireplace or extractor fan.
Do not use a separate ventilation fan or similar to extract air from the room where the
toilet is installed when using the Cinderella Classic toilet.
If you have open ventilation under the toilet, it may be advisable to use a mesh over the
hole to keep insects and vermin from entering the toilet. Make sure that the mesh is
not too fine as this will impede the air flow.
NOTE!
Cinderella supplies a specially designed "siphon" that fits
onto the elbow provided in the installation kit, this item
can be purchased as an accessory from any Cinderella
dealer. If installation is done from the interior, you will
need to connect the siphon to the elbow-piece to prevent
condensation and rainwater to drain onto the floor. Failure
to collect the condensation and emptying it regularly, may
result in damage to the floor.
he Cinderella Original installation Kit includes a flue
NOTE!
If the installed air vent has an adjustable opening, always
make sure to leave it open by a minimum of 75 mm when
operating the toilet.
The air inlet vent should