Attachment 2: Command allocation A
Value
Application
0 = Switch function with light key,
0 - 28
1 ... 28 = Switch function with F-key No. 1-28
30
Permanent-OFF (no function assigned)
31
Permanent-ON (except service mode)
129 -255 Extended function commands (binary state)
Anhang 3: CV 112, 122, 132, 142, 172, 182 – Dimming values + Servo function
Value
Application
1-100
percentage voltage at the output
120
standard servo function
121
standard servo function with end position switch off
122
precision servo function
123
precision servo function with end position switch off only A1(CV112) / A2(CV122)
124
standard servo with speed step operation
standard servo with speed step
125
and end position switch off
248
inverted standard servo function
inverted standard servo function
249
with end position switch off
250
inverted precision servo
252
inverted standard servo with speed step operation
inverted standard servo with speed step
253
and end position switch off
Attachment 4: CV 113, 123, 133, 143, 153, 163, 173, 183 – Condition
Value
Application
0
permanent activation (standard switch-on function)
1
forward only
2
backward only
4
standing only
Note
129 ≙ 1 / 255 ≙ 127
Note
100 = no dimming
only A1(CV112) / A2(CV122)
only A3(CV132) / A4(CV143)
only A3(CV132) / A4(CV143)
only A1(CV112) / A2(CV122)
only A3(CV132) / A4(CV143)
only A3(CV132) / A4(CV143)
Note
29