7. TROUBLESHOOTING
Symptom
Check the power connection in securely.
Check if the water level indicator lights
The unit is not
operating.
Check the room temperature.
Check the air filter for dirt.
Check if the air duct is blocked.
There is little
formation of
Check if the room temperature is below
condensate.
Set humidity level is higher than current
Overflow while moving the unit.
Water Leakage
Check if the drain hose is kinked or
Check if the unit is securely positioned.
Excessive Noise
Check if any loose, vibrating parts.
Noise sounds like water flowing.
E1
Temperature sensor failure
E2
Humidity sensor dampened or failure.
Display when Room temperature is
CL
Error
Display when Room temperature is
Codes
CH
Display when Room relative humidity is
LO
Display when Room relative humidity is
HI
Inspection
up?
20℃.
Humidity value.
bends.
below 5°C(41°F).
above35℃(95°F).
bellow 20%RH.
above 95%RH.
Insert the power cord securely into the wall
Outlet.
Empty the water tank and reinstall correctly.
The range of operating temperature is 5-
35℃.
Clean the air filter as necessary.
To clear the obstacle.
This is normal. Low humidity in low
temperature environment.
Set the humidity level below current
humidity value.
Empty the water tank before transport.
Straighten the hose to avoid a trap existing.
Place the unit on horizontal and firm
ground.
Secure and tight the parts.
Noise comes from flowing refrigerant. This
is normal.
Check connection or replace it.
To clean or replace the humidity sensor.
Normal. The compressor stops, and the fan
keeps running.
Normal. The compressor stops, and the fan
keeps running.
Normal. The compressor stops, and the fan
keeps running.
Normal. The compressor and the fan keep
running.
31
Solution