2. Configuring the Network Settings
3
Select the digit to be changed, and specify the
value.
IP ADDRESS SETTING
IP ADDRESS
192.168.000.052
• Use the lever (vw) to move "x" to the digit you want to change,
and use the lever (vw) to select the number.
• If you change the setting item, use the lever vw) to move "x" to
either end, and press the lever (vw) toward the same end. This
displays the IP ADDRESS SETTING screen, returning you to
2
step
.
4
Use the lever (xy) to select "MENU" – "BACK",
and press the [ENTER] button.
RReturns to the NETWORK SETTING screen.
5
To change the port number, use the lever (xy) to
select "PORT", and press the lever to the right (w).
NETWORK SETTING
IP ADDRESS
PORT
ALARM
MAC ADDRESS
08-00-7I-81-25-J2
RUse the same procedure as step
to your desired value (between 1 and 65535).
6
x
FIX
y
00080
x
OUT1/2
3
to change the port number
6
Use the lever (xy) to select "ALARM" and then
use the lever (vw) to select the alarm output
option.
NETWORK SETTING
IP ADDRESS
PORT
ALARM
MAC ADDRESS
08-00-7I-81-25-J2
• OFF:
Disables alarm output from the camera to the
network.
• OUT1:
Enables alarm output 1 to be sent to the network.
• OUT2:
Enables alarm output 2 to be sent to the network.
• OUT1/2:
Enables alarm outputs 1 and 2 to be sent to the
network (default setting).
7
Use the lever (xy) to select "MENU", use the
lever (vw) to select "END", and press [ENTER].
RCloses the settings screen and returns to the normal monitoring
screen.
• To return to the previous screen, select "BACK" and press the
[ENTER] button.
y
FIX
00090