Machine Type
Power tool equipped with 1/4 in. or 6 mm collet chuck for
use with various burrs for polishing and grinding - No other
use is permitted
Air Supply Requirements
1. Supply tool with 90 psig (6.3 bar) of clean, dry air. Higher
pressure drastically reduces tool life.
2. Connect tool to air line using pipe, hose and fitting sizes
shown in the diagram below.
3. Do not install a quick coupler directly into the grinder
throttle handle.
1/4" NPT
3/8" (10mm)
Lubrication
Use an air line lubricator with SAE #10 oil, adjusted to two
drops per minute. If an air line lubricator cannot be used,
add air motor oil to the inlet once a day.
Maintenance
1. After first year disassemble and inspect air motor every
three months if the tool is used every day. Replace
damaged or worn parts.
2. High wear parts are underlined in the parts list.
3. To keep downtime to a minimum, the following service kits
are recommended;
Tune-Up Kit:
8940168879 (CP9105QB & CP9110QB)
8940168880 (CP9106QB & CP9108QB)
8940168892 (CP9111QB & CP9112QB)
Original Instructions
Copyright 2010, Chicago Pneumatic Tool Co. LLC
All rights reserved. Any unauthorized use or copying of the contents or
part thereof is prohibited. This applies in particular to trademarks, model
denominations, part numbers and drawings. Use only authorized parts.
Any damage or malfunction caused by the use of unauthorized parts is
not covered by Warranty or Product Liability.
1/2" (12mm)
CA048362 (1/2") NPT
1/2" (12mm)
CA048360 (1/2") NPT
CA048361 (1/2") NPT
Technical Data,
Noise & Vibration Declaration
Free Speed
RPM
CP9105QB
27000
CP9106QB
22000
CP9108QB
22000
CP9110QB
25000
CP9111QB
22000
CP9112QB
22000
1/4 in. or 6 mm collet
Air pressure 90 psi (6.3 bar)
Sound pressure level measured at free speed, uncertainty 3 dB(A),
in accordance with EN ISO 15744. For sound power, add 11 dB(A).
Vibration value re. ISO 20643.
Declaration of noise and vibration emission
All values are current as of the date of this publication. For the latest
information please visit cp.com.
These declared values were obtained by laboratory type testing in
accordance with the stated standards and are suitable for comparison
with the declared values of other tools tested in accordance with the
same standards. These declared values are not adequate for use in risk
assessments and values measured in individual work places may be
higher. The actual exposure values and risk of harm experienced by an
individual user are unique and depend upon the way the user works, the
workpiece and the workstation design, as well upon the exposure time
and the physical condition of the user.
We, Chicago Pneumatic, cannot be held liable for the consequences
of using the declared values, instead of values reflecting the actual
exposure, in an individual risk assessment in a work place situation over
which we have no control.
This tool may cause hand-arm vibration syndrome if its use is not
adequately managed. An EU guide to managing hand-arm vibration can
be found at http://www.humanvibration.com/EU/VIBGUIDE.htm
We recommend a programme of health surveillance to detect early
symptoms which may relate to noise or vibration exposure, so that
management procedures can be modified to help prevent future
impairment.
MANUFACTURER'S LIMITED WARRANTY
Limited Warranty: The "Products" of the Chicago Pneumatic Tool
Co. LLC ("CP") are warranted to be free from defects in material and
workmanship for one year from the date of purchase. This Warranty
applies only to Products purchased new from CP or its authorized dealers.
Of course, this Warranty does not apply to products which have been
abused, misused, modified, or repaired by someone other than CP or its
Authorized Service Representatives. If a CP Product proves defective in
material or workmanship within one year after purchase, return it to any
CP Factory Service Center or Authorized Service Center for CP tools,
transportation prepaid, enclosing your name and address, adequate
proof of date of purchase, and a short description of the defect. CP will,
at its option, repair or replace defective Products free of charge. Repairs
or replacements are warranted as described above for the remainder of
the original warranty period. CP's sole liability and your exclusive remedy
under this Warranty is limited to repair or replacement of the defective
Product. (There Are No Other Warranties Expressed Or Implied And
CP Shall Not Be Liable For Incidental, Consequential, Or Special
Damages, Or Any Other Damages, Costs Or Expenses Excepting
Only The Cost Or Expense Of Repair Or Replacement As Described
Above.)
CP91QB Series
Mini Die Grinder
Vibration
Noise
dB
a m/s
k m/s
2
3.6
80
80
5.1
2.6
80
4.91
3.1
80
4.92
2.5
80
3.7
1.7
80
2.7
1.2
2