LCD Screen Operation - Section C
VII. Advanced options
Pump anti cavitation mode
This feature sends two electric pulses every 5 minutes to the pump.
This prevents the build up of air bubbles inside the pump and en-
sures an even fl ow of hot water at the tap.
Note: This function can only be disabled if the hot water is set below
98 °C.
Power Pulsing mode
This is a default set point control feature which ensures the hot
water is maintained as close as possible to the set point. This is
achieved by applying a closer tolerance to the set point temperature
range. It is estimated that 1 in 15,000 installations could experience
intermittent fl ickering lights, during the boiling water recovery peri-
od. Disabling may overcome the fl ickering lights, however, the unit
may experience increased steaming.
Note: This function can only be disabled if the hot water is set below
98.5 °C.

Fan speed adjustment

If the undersink unit is operating near 35 °C then the fan speed must
be 100%. The fan speed may be adjusted for quieter operation only if
the operating temperatures are considerably lower than 35°C.
In this screen (depending on the set temperatures) you may set
some parameters or enable / disable the functions.
> Press [Anti Cavitation] to enable / disable the function.
> Press [Power Pulsing] to enable / disable the function.
> Press [Fan] to adjust the fan speed to 50%, 75% or 100%.
1. Press [MENU] for main menu.
2. Press [Install].
3. Press [Advanced Options].