Herunterladen Inhalt Inhalt Diese Seite drucken

Underside; Installation; Installing/Replacing The Lamp - EuroLite Theatre Spot 300 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Underside

(1) Color filter frame
(2) Clip-to-hold clamps
(3) Focus screw
(4) Fixation screw
(5) Housing
(6) Ventilation slots
(7) Handle

INSTALLATION

Installing/Replacing the lamp

Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
During the operation, the lamp reaches temperatures of up to 450° C.
For the installation, you need a 230V/300W or 230V/500W GY-9.5 lamp.
Procedure:
Step 1: Unscrew the fixation-screw of the protection-cover on the rear of the device.
Step 2: Remove the protection-cover.
Step 3: If replacing the lamp, remove the old lamp from the socket.
Step 4: Insert the new 230V/300W or 230V/500W GY-9.5 lamp into the lamp-socket.
Step 5: Replace the protection-cover and tighten the screw.
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened protection-cover!
16/19
00057637.DOC, Version 3.0

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Theatre spot 500

Inhaltsverzeichnis